Metagenomic Analysis Reveals Clinical SARS-CoV-2 Infection and Bacterial or Viral Superinfection and Colonization.
Аннотация
BACKGROUND
More than 2 months separated the initial description of SARS-CoV-2 and discovery of its widespread dissemination in the United States. Despite this lengthy interval, implementation of specific quantitative reverse transcription (qRT)-PCR-based SARS-CoV-2 tests in the US has been slow, and testing is still not widely available. Metagenomic sequencing offers the promise of unbiased detection of emerging pathogens, without requiring prior knowledge of the identity of the responsible agent or its genomic sequence.
METHODS
To evaluate metagenomic approaches in the context of the current SARS-CoV-2 epidemic, laboratory-confirmed positive and negative samples from Seattle, WA were evaluated by metagenomic sequencing, with comparison to a 2019 reference genomic database created before the emergence of SARS-CoV-2.
RESULTS
Within 36 h our results showed clear identification of a novel human Betacoronavirus, closely related to known Betacoronaviruses of bats, in laboratory-proven cases of SARS-CoV-2. A subset of samples also showed superinfection or colonization with human parainfluenza virus 3 or Moraxella species, highlighting the need to test directly for SARS-CoV-2 as opposed to ruling out an infection using a viral respiratory panel. Samples negative for SARS-CoV-2 by RT-PCR were also negative by metagenomic analysis, and positive for Rhinovirus A and C. Unlike targeted SARS-CoV-2 qRT-PCR testing, metagenomic analysis of these SARS-CoV-2 negative samples identified candidate etiological agents for the patients' respiratory symptoms.
CONCLUSION
Taken together, these results demonstrate the value of metagenomic analysis in the monitoring and response to this and future viral pandemics.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.