MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.radonc.2022.09.005

Медицинская библиотека · Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2022

The role of multiple anatomical scenarios in plan optimization for carbon ion radiotherapy of pancreatic cancer.

Molinelli Silvia, Vai Alessandro, Russo Stefania, Loap Pierre, Meschini Giorgia, Paganelli Chiara, Barcellini Amelia, Vitolo Viviana, Orlandi Ester, Ciocca Mario

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE /

OBJECTIVE

To quantify benefits of robust optimization on multiple 4DCT acquisitions combined with off-line treatment adaptation for neoadjuvant carbon ion therapy (CIRT) of pancreatic cancer.

MATERIAL/

METHODS

For 10 previously treated patients, 4DCTs were acquired around -15 (CTPlan), -5 (RE1), -1 (RE2) and +6 (RE3) days from RT start. Treatment plans were newly optimized to a dose prescription of 38.4 Gy(RBE) (8 fractions) with a constraint of 38 Gy(RBE) to 1% of the gastrointestinal organs at risk volume (D1%). Three strategies were tested: (A) robust optimization on CTPlan maximum exhale (0Ex) with 3 mm set-up, 3% range uncertainty, including 30%-inhale; (B) addition of the RE1-0Ex scenario; (C) plan recalculation at each REi and adaptation (RPi) according to deviation thresholds from clinical goals. The cumulative variation of target coverage and GI-OARs doses was evaluated. Duodenum contours of all 4DCTs of each patient were registered on CTPlan-0Ex. The capacity of pre-RT acquisitions to predict duodenum position was investigated by computing the intersection of contours at CTplan, RE1, or their union, with respect to subsequent 4DCTs and the CTV, coupled with increasing margin.

RESULTS

(A) No recalculation exceeded the D1% constraint. (B) The inclusion of RE1-0Ex in the optimization problem improved inter-fraction robustness on a patient-specific basis, but was non-significant on average. (C) Half of the plans would be re-optimized to recover target coverage and/or minimize duodenum dose, at least once. A significant difference was observed between pre-RT duodenum contours when intersecting subsequent contours, either with a margin expansion.

CONCLUSION

Anatomical variations highlighted at multiple REi proved that a fast and efficient online adaptation is essential to optimize treatment quality of CIRT for pancreatic cancer.

Для цитирования: Molinelli Silvia, Vai Alessandro, Russo Stefania, Loap Pierre, Meschini Giorgia, Paganelli Chiara, Barcellini Amelia, Vitolo Viviana, Orlandi Ester, Ciocca Mario. The role of multiple anatomical scenarios in plan optimization for carbon ion radiotherapy of pancreatic cancer.. Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 2022. DOI: 10.1016/j.radonc.2022.09.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.