MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jum.14411

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2017

The Rate of Cervical Length Shortening in the Management of Vasa Previa.

Maymon Ron, Melcer Yaakov, Tovbin Josef, Pekar-Zlotin Marina, Smorgick Noam, Jauniaux Eric

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

There is no consensus about the optimal surveillance strategy in women with a diagnosis of vasa previa. The aim of this study was to evaluate the role of the rate of change in cervical length measurements in the management of singleton pregnancies with a diagnosis of vasa previa.

METHODS

We performed a retrospective case-control study of our databases for pregnancies with a prenatal diagnosis of vasa previa that were followed with transvaginal sonography for cervical length and evaluated the impact of the changes in cervical length on the need for emergency cesarean delivery.

RESULTS

The cohort included 29 singleton pregnancies with a prenatal diagnosis of vasa previa in the second trimester. There were 14 and 15 pregnancies that underwent elective and emergency cesarean delivery, respectively. The rate of cervical length shortening was significantly slower for women with elective compared to emergency cesarean delivery (median [range], 0.7 [0.1-2.0] versus 1.5 [0.25-3.0] mm/wk; P = .011). For each additional millimeter-per-week decrease in cervical length, the odds of emergency cesarean delivery increased by 6.50 (95% confidence interval, 1.02-41.20). The receiver operating characteristic curve for the rate of cervical length shortening in the prediction of emergency cesarean delivery yielded an area under the curve of 0.85 (95% confidence interval, 0.69-0.99).

CONCLUSIONS

Our findings indicate an association between the rate of cervical length shortening and the risk of emergency cesarean delivery in pregnancies with a diagnosis of vasa previa in the second trimester. Further multicentric studies are required to validate our data prospectively and, in particular, the role of serial cervical length measurements in determining the optimal delivery time for individual cases.

Для цитирования: Maymon Ron, Melcer Yaakov, Tovbin Josef, Pekar-Zlotin Marina, Smorgick Noam, Jauniaux Eric. The Rate of Cervical Length Shortening in the Management of Vasa Previa.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2017. DOI: 10.1002/jum.14411.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.