Sonographic Measurement of Cervical Volume in Pregnant Women at High Risk of Preterm Birth Using a Geometric Formula for a Frustum Versus 3-Dimensional Automated Virtual Organ Computer-Aided Analysis.

Ahmed Ahmed I, Aldhaheri Sarah R, Rodriguez-Kovacs Javier, Narasimhulu Deepa, Putra Manesha, Minkoff Howard, Haberman Shoshana

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare cervical volume measurements by 3-dimensional (3D) sonography using Virtual Organ computer-aided analysis (VOCAL; GE Healthcare, Milwaukee, WI) versus a manual method using a geometric formula for a frustum.

METHODS

We included 142 asymptomatic pregnant women at 16 to 24 weeks gestation at high risk for preterm birth. With a Voluson 730 Expert system (GE Healthcare), they underwent 2-dimensional (2D) transvaginal sonographic cervical length measurements and 3D cervical volume acquisition. The stored volumes were processed by VOCAL on a surface tablet. Cervical volume was manually calculated from the 2D images by using the formula V = 1/3 × π × h × (r12  + r22  + r1 × r2), where V represents cervical volume; π was approximated as 3.14159; h, cervical length; r1, radius at the internal os; and r2, radius at the external os.

RESULTS

Cervical volume was lower when obtained manually than by VOCAL, with a coefficient of variation of 30%, a mean difference of 10.1 ± 14.9 cm3 (P < .0001), and a poor interclass correlation coefficient of 0.62 (95% confidence interval [CI], 0.31 to 0.78). Both methods had good reproducibility; however, VOCAL had wider limits of agreement. A positive correlation was found between both methods (r = 0.63; P < .0001). No correlation was found between cervical length by 2D transvaginal ultrasound and cervical volume by the VOCAL technique (r = 0.06; 95% CI, -0.10 to 0.22) or cervical volume by the manual method (r = 0.2; 95% CI, 0.08 to 0.39).

CONCLUSIONS

The cervix represents a frustum (truncated cone, r1 is not equal to r2) in shape rather than a cylinder. Both methods are reproducible; VOCAL is less reliable but provides higher values of cervical volume.

Для цитирования: Ahmed Ahmed I, Aldhaheri Sarah R, Rodriguez-Kovacs Javier, Narasimhulu Deepa, Putra Manesha, Minkoff Howard, Haberman Shoshana. Sonographic Measurement of Cervical Volume in Pregnant Women at High Risk of Preterm Birth Using a Geometric Formula for a Frustum Versus 3-Dimensional Automated Virtual Organ Computer-Aided Analysis.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2017. DOI: 10.1002/jum.14253.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.