Efficacy and safety of novel low-intensity pulsed ultrasound (LIPUS) in treating mild to moderate erectile dysfunction: a multicenter, randomized, double-blind, sham-controlled clinical study.

Cui Wanshou, Li Huixi, Guan Ruili, Li Meng, Yang Bicheng, Xu Zhanwei, Lin Maofan, Tian Long, Zhang Xiaodong, Li Bao, Liu Weiguang, Dong Zhilong, Wang Zhiping, Zheng Tao, Zhang Weixing, Lin Guiting, Guo Yinglu, Xin Zhongcheng

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In our previous study, a novel low-intensity pulsed ultrasound (LIPUS) therapeutic device has been shown to improve erectile function non-invasively in a diabetic-induced erectile dysfunction (ED) animal model.

METHODS

In order to investigate the efficacy and safety of LIPUS in the clinical treatment of patients with ED, a multicenter, randomized, double-blind, sham-treated, controlled clinical study was conducted at five medical centers, and 120 patients with mild to moderate ED were enrolled in the study. Patients were randomized into a sham-treated control group (40 patients) or a LIPUS-treated group (80 patients). LIPUS or sham treatment was applied to both sides of the penis shaft and crus for 5 min in each area, twice a week for four weeks. Assessment of efficacy and safety were evaluated using IIEF-5, Sexual Encounter Profile (SEP)-questionnaires 2/3, Global Assessment Question (GAQ), Erectile Hardness Score (EHS), Erection Quality Scale (EQS) score, and pain assessment [Visual Analogue Scale/Score (VAS)].

RESULTS

Ten patients in LIPUS treatment group and 6 patients in sham treatment control group were excluded and the dropout rate is 13.33%. Response to treatment was identified as IIEF-5 score increased more than 2/3/4 points of post-treatment (12W) compared to pre-treatment (0W). The response rate in treatment group was 54/80 (67.50%), which was significantly higher than control group 8/40 (20.00%) at 12 weeks (FAS analysis). The percentage of patients with positive answers to SEP-3 (successful vaginal intercourse) were 58.97%, 64.1%, and 73.08% 4, 8, and 12 weeks after treatment which were significantly higher than 28.95%, 31.58%, and 28.95% respectively in control group (FAS, P<0.05). The positive responsive rates for GAQ in treatment group were about 2 to 3 times of that in control group (P<0.05). No treatment-related adverse events (AEs) were found, including local petechia or ecchymosis and hematuria.

CONCLUSIONS

Current study indicates that LIPUS can safely and effectively treat patients with mild to moderate ED without significant AEs, which is related to the mechanical force of LIPUS and can restore the pathological changes of the corpus cavernosum. LIPUS is a promising alternative treatment for ED treatment in the near future, while further research is remanded.

Для цитирования: Cui Wanshou, Li Huixi, Guan Ruili, Li Meng, Yang Bicheng, Xu Zhanwei, Lin Maofan, Tian Long, Zhang Xiaodong, Li Bao, Liu Weiguang, Dong Zhilong, Wang Zhiping, Zheng Tao, Zhang Weixing, Lin Guiting, Guo Yinglu, Xin Zhongcheng. Efficacy and safety of novel low-intensity pulsed ultrasound (LIPUS) in treating mild to moderate erectile dysfunction: a multicenter, randomized, double-blind, sham-controlled clinical study.. Translational andrology and urology. 2019. DOI: 10.21037/tau.2019.07.03.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.