PURPOSE: Examine the antiseptic effect of long-term low-concentration (0.3%) povidone-iodine (PI) before cataract surgery.

SETTING

St. Olavs Hospital, Trondheim University Hospital, Trondheim, Norway.

DESIGN

Single-armed prospective clinical study.

METHODS

Repeated measure of preoperative conjunctival samples from 51 participants were obtained the day before surgery (T1), the day of surgery after treatment with ophthalmic NSAID (T2), and after additional treatment with low-concentration PI (T3) given by placing a pledget soaked in a mix of eye-drops in fornix inferior for 20 min.

RESULTS

Before surgery, and before any type of treatment (T1), bacterial growth (≥5 BC) in the conjunctiva was identified in 36 (66.7%) of the participants. After treatment with ophthalmic NSAID (T2), and after additional treatment with low-concentration PI (T3), bacteria were identified in 31 (60.8%) and 12 (23.4%) participants, respectively. All except one of the participants with a measurable change from T2 to T3 (n = 31, 60.8% of total sample), experienced a decrease in number of bacterial colonies (BC) after treatment with low-concentration PI (96.8 vs. 3.2%, p < 0.001). A complete removal of bacteria was seen in 20 (n = 31, 64,5%) of the colonized participants after treatment with PI.

CONCLUSIONS

Preoperative treatment with long-term, low-concentration PI applied via a depot device in fornix inferior, seem to be an easy and effective way to reduce the number of BC in the conjunctiva.

Для цитирования: Wass Simon, Albrektsen Grethe, Ødegård Maria Tjåland, Sand Mari, Austeng Dordi. Antiseptic effect of low-concentration povidone-iodine applied with a depot device in the conjunctiva before cataract surgery.. Eye (London, England). 2018. DOI: 10.1038/s41433-018-0198-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.