MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10439-020-02528-7

Медицинская библиотека · Annals of biomedical engineering · 2020

An Instrumented Urethral Catheter with a Distributed Array of Iontronic Force Sensors.

Zhang Ye, Ahmadi Mahdi, Timm Gerald, Sezen Serdar, Rajamani Rajesh

СтатьяПеревод пока не подготовлен

Аннотация

This paper develops a novel instrumented urethral catheter with an array of force sensors for measuring the distributed pressure in a human urethra. The catheter and integrated portions of the force sensors are fabricated by the use of 3D printing using a combination of both soft and hard polymer substrates. Other portions of the force sensors consisting of electrodes and electrolytes are fabricated separately and assembled on top of the 3D-printed catheter to create a soft flexible device. The force sensors use a novel supercapacitive (iontronic) sensing mechanism in which the contact area between a pair of electrodes and a paper-based electrolyte changes in response to force. This provides a highly sensitive measure of force that is immune to parasitic noise from liquids. The developed catheter is tested using a force calibration test rig, a cuff-based pressure application device, an extracted bladder and urethra from a sheep and by dipping inside a beaker of water. The force sensors are found to have a sensitivity of 30-50 nF/N, which is 1000 times larger than that of traditional capacitive force sensors. They exhibit negligible capacitance change when dipped completely in water. The pressure cuff tests and the extracted sheep tissue tests also verify the ability of the sensor array to work reliably in providing distributed force measurements. The developed catheter could help diagnose ailments related to urinary incontinence and inadequate urethral closure pressure.

Для цитирования: Zhang Ye, Ahmadi Mahdi, Timm Gerald, Sezen Serdar, Rajamani Rajesh. An Instrumented Urethral Catheter with a Distributed Array of Iontronic Force Sensors.. Annals of biomedical engineering. 2020. DOI: 10.1007/s10439-020-02528-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.