MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0196968

Медицинская библиотека · PloS one · 2018

The impact of conjunctival flap method and drainage cannula diameter on bleb survival in the rabbit model.

Rodgers Cooper D, Meyer Alissa M, Rosenberg Nicole C, Lukowski Zachary L, Schaefer Jamie L, Martorana Gina M, Levine Monica A, Meyers Craig A, Sherwood Mark B

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To examine the effect of cannula diameter and conjunctival flap method on bleb survival in rabbits undergoing cannula-based glaucoma filtration surgery (GFS).

METHODS

Twelve New Zealand White rabbits underwent GFS in both eyes. The twenty-four eyes were divided into four groups. Two of the four groups (N = 12) received limbus-based conjunctival flaps (LBCF), and the other two (N = 12) received fornix-based conjunctival flaps (FBCF). Six FBCF rabbit eyes were implanted with 22-gauge drainage tubes, and the other six were implanted with 26-gauge tubes. Likewise, six LBCF rabbits received 22-gauge drainage tubes and six received 26-gauge tubes. Filtration blebs were evaluated every three days by a masked observer. Bleb failure was defined as the primary endpoint in this study and was recorded after two consecutive flat bleb evaluations.

RESULTS

Group 1 (LBCF, 22- gauge cannula) had a mean bleb survival time (Mean ± SD) of 18.7 ± 2.9 days. Group 2 (LBCF, 26-gauge cannula) also had a mean bleb survival time of 18.7 ± 2.9 days. Group 3 (FBCF, 22-gauge cannula) had a mean bleb survival time of 19.2 ± 3.8 days. Group 4 (FBCF, 26-gauge cannula) had a mean bleb survival time of 19.7 ± 4.1 days. A 2-way analysis of variance showed that neither surgical approach nor cannula gauge made a statistically significant difference in bleb survival time (P = 0.634 and P = 0.874). Additionally, there was no significant interaction between cannula gauge and conjunctival flap approach (P = 0.874), suggesting that there was not a combination of drainage gauge and conjunctival flap method that produced superior bleb survival.

CONCLUSION

Limbus and fornix-based conjunctival flaps are equally effective in promoting bleb survival using both 22 and 26-gauge cannulas in the rabbit model. The 26-gauge drainage tube may be preferred because its smaller size facilitates the implantation process, reducing the risk of corneal contact.

Для цитирования: Rodgers Cooper D, Meyer Alissa M, Rosenberg Nicole C, Lukowski Zachary L, Schaefer Jamie L, Martorana Gina M, Levine Monica A, Meyers Craig A, Sherwood Mark B. The impact of conjunctival flap method and drainage cannula diameter on bleb survival in the rabbit model.. PloS one. 2018. DOI: 10.1371/journal.pone.0196968.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление