MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.65.11.2

Медицинская библиотека · Investigative ophthalmology & visual science · 2024

Lens Power and Associated Factors in Nonhuman Primate Subjects: A Cross-sectional Study.

Zhu Yingting, Xie Rui, Zhang Qi, Zhang Yuan, Ye Guitong, Xu Liangzhi, Hou Simeng, Liu Wei, Huang Zhiwei, Wu Jian, Zhuo Yehong

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: We aimed to examine the normative profile of crystalline lens power (LP) and its associations with ocular biometric parameters including age, axial length (AL), spherical equivalent refraction (SE), corneal radius (CR), lens thickness, anterior chamber depth, and AL/CR ratio among a cynomolgus monkey colony.

METHODS

This population-based cross-sectional Non-human Primate Eye Study recruited middle-aged subjects in South China. All included macaques underwent a detailed ophthalmic examination. LP was calculated using the modified Bennett's formula, with biometry data from an autorefractometer and A-scan. SPSS version 25.0 was used for statistical analysis.

RESULTS

A total of 301 macaques with an average age of 18.75 ± 2.95 years were collected in this study. The mean LP was 25.40 ± 2.96 D. Greater LP was independently associated with younger age, longer AL, and lower SE (P = 0.028, P = 0.025, and P = 0.034, respectively). LP showed a positive correlation with age, SE, CR, AL, lens thickness, and anterior chamber depth, whereas no correlation was observed between LP and AL/CR ratio.

CONCLUSIONS

Our results suggested the LP distribution in the nonhuman primate colony and indicated that AL and SE strongly influenced the rate of LP. Therefore, this study contributed to a deeper understanding of the relative significance of the LP on the optics of the crystalline lens study.

Для цитирования: Zhu Yingting, Xie Rui, Zhang Qi, Zhang Yuan, Ye Guitong, Xu Liangzhi, Hou Simeng, Liu Wei, Huang Zhiwei, Wu Jian, Zhuo Yehong. Lens Power and Associated Factors in Nonhuman Primate Subjects: A Cross-sectional Study.. Investigative ophthalmology & visual science. 2024. DOI: 10.1167/iovs.65.11.2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.