MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/tvst.13.8.40

Медицинская библиотека · Translational vision science & technology · 2024

Automatic Determination of Endothelial Cell Density From Donor Cornea Endothelial Cell Images.

Benetz Beth Ann M, Shivade Ved S, Joseph Naomi M, Romig Nathan J, McCormick John C, Chen Jiawei, Titus Michael S, Sawant Onkar B, Clover Jameson M, Yoganathan Nathan, Menegay Harry J, O'Brien Robert C, Wilson David L, Lass Jonathan H

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine endothelial cell density (ECD) from real-world donor cornea endothelial cell (EC) images using a self-supervised deep learning segmentation model.

METHODS

Two eye banks (Eversight, VisionGift) provided 15,138 single, unique EC images from 8169 donors along with their demographics, tissue characteristics, and ECD. This dataset was utilized for self-supervised training and deep learning inference. The Cornea Image Analysis Reading Center (CIARC) provided a second dataset of 174 donor EC images based on image and tissue quality. These images were used to train a supervised deep learning cell border segmentation model. Evaluation between manual and automated determination of ECD was restricted to the 1939 test EC images with at least 100 cells counted by both methods.

RESULTS

The ECD measurements from both methods were in excellent agreement with rc of 0.77 (95% confidence interval [CI], 0.75-0.79; P < 0.001) and bias of 123 cells/mm2 (95% CI, 114-131; P < 0.001); 81% of the automated ECD values were within 10% of the manual ECD values. When the analysis was further restricted to the cropped image, the rc was 0.88 (95% CI, 0.87-0.89; P < 0.001), bias was 46 cells/mm2 (95% CI, 39-53; P < 0.001), and 93% of the automated ECD values were within 10% of the manual ECD values.

CONCLUSIONS

Deep learning analysis provides accurate ECDs of donor images, potentially reducing analysis time and training requirements.

TRANSLATIONAL RELEVANCE: The approach of this study, a robust methodology for automatically evaluating donor cornea EC images, could expand the quantitative determination of endothelial health beyond ECD.

Для цитирования: Benetz Beth Ann M, Shivade Ved S, Joseph Naomi M, Romig Nathan J, McCormick John C, Chen Jiawei, Titus Michael S, Sawant Onkar B, Clover Jameson M, Yoganathan Nathan, Menegay Harry J, O'Brien Robert C, Wilson David L, Lass Jonathan H. Automatic Determination of Endothelial Cell Density From Donor Cornea Endothelial Cell Images.. Translational vision science & technology. 2024. DOI: 10.1167/tvst.13.8.40.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.