MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1167/iovs.04-0154

Медицинская библиотека · Investigative ophthalmology & visual science · 2004

Factors influencing intraocular pressure in cultured human anterior segments.

Bahler Cindy K, Fautsch Michael P, Hann Cheryl R, Johnson Douglas H

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine why variations in intraocular pressure (IOP) occur in cultured human anterior segments despite a constant rate of infusion of culture medium. Two types of variations occur: an initial elevation of IOP and small changes in baseline IOP.

METHODS

Anterior segments from human eyes were placed in perfusion organ culture. In cultures with initially high IOP, eyes were fixed at the high IOP level and histologic examination performed. In other cultures with high initial IOP, effluent medium was collected and subsequently reinfused after IOP had decreased to baseline. In cultures with stable baseline IOP, cell fragments from monolayer-cultured cells, or human genomic DNA, were infused at concentrations equivalent to 30,000 to 300,000 cells.

RESULTS

Electron microscopy of initially high-pressure cultures revealed scattered cell debris throughout the meshwork in greater amounts than found in eyes without initially high IOP. Reinfusion of effluent media from cultures with high initial pressures caused elevation of IOP. Centrifugation of effluent media lessened this elevation of IOP. In cultures with stable baseline IOP, infusion of cell fragments or genomic DNA raised IOP in a dose-dependent manner, with elevation of IOP for a minimum of 24 hours.

CONCLUSIONS

Cell debris can elevate IOP during the initial culture period, and after baseline pressures are established. Cell fragments and DNA increase IOP in a dose-dependent manner. The variations in baseline IOP seen during culture are probably caused by cell fragments and debris from dying cells in the meshwork, ciliary body, and other anterior segment tissues.

Для цитирования: Bahler Cindy K, Fautsch Michael P, Hann Cheryl R, Johnson Douglas H. Factors influencing intraocular pressure in cultured human anterior segments.. Investigative ophthalmology & visual science. 2004. DOI: 10.1167/iovs.04-0154.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.