MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/smll.74959

Медицинская библиотека · Small (Weinheim an der Bergstrasse, Germany) · 2026

Shell Thickness Regulated Non-Enzymatic Au@AgNanocube Electrochemical Sensor for Sensitive and Simultaneous Analytical Detection of Three Important Kidney Dysfunction Biomarkers.

Roy Anuradha, Ghosh Tanmay, Tripathi Ayushi, Paul Provakar, Nayek Sanjoy, Das Tisita, Senapati Dulal

СтатьяПеревод пока не подготовлен

Аннотация

Developing plasmonic metal-based electrocatalysts for selective and sensitive biomolecular sensing remains an important research focus. Herein, a facile non-enzymatic electrochemical sensing platform based on Au@Agn core-shell nanocubes (NCs)-modified glassy carbon electrode is reported for the simultaneous detection of three kidney dysfunction biomarkers (KDBs): creatinine (Crn), uric acid (UA), and xanthine (Xan). Among different shell thicknesses, Au@Ag3NC exhibited superior electrocatalytic activity, showing well-resolved diffusion-controlled oxidation peaks, enhanced current response, interference-free detection, and good long-term stability. The enhanced catalytic performance is attributed to interfacial tensile strain and electronegativity differences between the Au core and Ag shell, generating a positively charged surface which is favorable for electron rich analyte adsorption. Density functional theory (DFT) calculations further revealed enhanced charge transfer between the adsorbates (KDBs) and Au@AgnNC surfaces with increasing Ag-shell thickness, supporting the experimental observations. Differential pulse voltammetry (DPV) demonstrated a wide linear detection range from nM to mM concentrations with limits of detection (LOD) of 20.6, 28.0, and 34.3 nM for Crn, UA, and Xan, respectively. The proposed nanocatalytic platform also showed satisfactory recovery in human bio-fluid analysis, highlighting its potential for multiplexed kidney biomarker sensing.

Для цитирования: Roy Anuradha, Ghosh Tanmay, Tripathi Ayushi, Paul Provakar, Nayek Sanjoy, Das Tisita, Senapati Dulal. Shell Thickness Regulated Non-Enzymatic Au@AgNanocube Electrochemical Sensor for Sensitive and Simultaneous Analytical Detection of Three Important Kidney Dysfunction Biomarkers.. Small (Weinheim an der Bergstrasse, Germany). 2026. DOI: 10.1002/smll.74959.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.