Медицинская библиотека · Journal of applied clinical medical physics · 2026

Accumulated dose on daily iCBCT for rectal cancer: Effects of inter-fraction bowel cavity motion volume.

Zeng Hongwei, E Xiangyu, Zeng Su, Feng Yue, Yu Jingping, Lv Minghe, Zhao Ruping

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

To assess how inter-fraction bowel cavity (BC) motion volume influences accumulated dose in rectal cancer radiotherapy and to translate these effects into a clinically interpretable risk construct for acute bowel toxicity.

METHODS

This retrospective cohort included 28 consecutive rectal cancer patients treated with 50 Gy in 25 fractions on a Halcyon v3.0 linac with daily iterative cone beam CT (iCBCT). Patients with > 5% bladder-volume or > 8% external-contour variation across the course were excluded. For each fraction, per-fraction dose was recalculated on the iCBCT using a scanner-specific HU-relative electron density calibration, rigidly aligned to the planning CT (pCT), deformably registered, and voxel-wise accumulated on pCT. Dosimetric endpoints were PTV D2%, D50%, D98% and whole-bowel (WB) D0.03cc, D150cc. Associations between inter-fraction BC motion volume change (ΔVBC) and accumulated dose difference (ΔD) were quantified using Spearman's f and ordinary-least-squares slopes (Gy per 10% BC expansion); same-day effects were estimated with patient fixed-effects models. To account for multiple testing, p-values for the five primary endpoints were adjusted using the Benjamini-Hochberg false discovery rate (FDR). Clinical relevance was assessed with a published logistic normal-tissue complication probability (NTCP) model based on WB V45, defined as the WB volume receiving ≥ 45 Gy.

RESULTS

Accumulated dose analyses showed selective elevation of high-dose metrics with preservation of near-minimum target coverage. Compared with the plan, accumulated PTV D2% and D50% increased by 0.87 Gy and 0.61 Gy, respectively, whereas PTV D98% exhibited no meaningful change. WB D0.03cc and D150cc increased by 1.21 Gy and 1.18 Gy, respectively. Inter-fraction BC expansion was strongly associated with high-dose escalation: for each 10% increase in BC volume, accumulated WB D0.03cc increased by 0.31 Gy (95% CI 0.18-0.44; ρ = 0.78) and PTV D2% by 0.29 Gy (0.15-0.37; ρ = 0.66). After FDR adjustment, no endpoint met p < 0.05, but the strongest associations (PTV D2%, WB D0.03cc) remained near-significant and directionally consistent with large, biologically plausible effect sizes. Application of the WB V45 NTCP model indicated modest but consistent risk increments after accumulation, with NTCP for ≥ grade 2 toxicity increasing from 0.75 to 0.79 (+0.04; p = 0.001) and NTCP for grade 3 toxicity increasing from 0.80 to 0.84 (+0.04; p = 0.002).

CONCLUSION

Daily iCBCT-based dose accumulation identifies inter-fraction BC motion volume as a selective driver of high-dose escalation to the PTV and WB while largely preserving near-minimum target coverage. Accumulated WB V45 may serve as a practical, delivery-based marker for on-treatment surveillance and risk-adapted intervention, complementing plan-based evaluation in rectal cancer radiotherapy.

Для цитирования: Zeng Hongwei, E Xiangyu, Zeng Su, Feng Yue, Yu Jingping, Lv Minghe, Zhao Ruping. Accumulated dose on daily iCBCT for rectal cancer: Effects of inter-fraction bowel cavity motion volume.. Journal of applied clinical medical physics. 2026. DOI: 10.1002/acm2.70524.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.