MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00464-020-07931-8

Медицинская библиотека · Surgical endoscopy · 2020

Simultaneous multipurpose fluorescence imaging with IRDye® 800BK during laparoscopic surgery.

Al-Taher Mahdi, Barberio Manuel, Felli Eric, Agnus Vincent, Ashoka Anila Hoskere, Gioux Sylvain, Klymchenko Andrey, Bouvy Nicole, Stassen Laurents, Marescaux Jacques, Diana Michele

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

IRDye® 800BK is a fluorophore, currently undergoing clinical translation, which has both biliary and renal clearance. To date, there is no description of a fluorophore, which can be simultaneously used for non-invasive, near-infrared fluorescence-based (NIRF) visualization of different structures and perfusion evaluation. The purpose of this study was to evaluate IRDye® 800BK for the simultaneous assessment of bowel perfusion, lymphography, ureter and bile duct delineation.

METHODS

Six pigs received a 0.15 mg/kg dye as a single bolus intravenous injection (IV). With the FLER (fluorescence-based enhanced reality) software, fluorescence intensity (FI) of 5 regions of interest (ROI) in an ischemic bowel loop was measured along with the time to reach the FI peak, and capillary lactate was measured from the same ROI, followed by the assessment of the ureters and bile ducts for a maximal duration of 180 min after dye administration. In 3 animals, the procedure was initiated via gastroscopic injection of a 0.6 mg (1 mg/mL) dye in the gastric submucosa followed by lymphography in a NIRF setting.

RESULTS

Excellent visualization of the ureters and bowel perfusion was obtained under NIRF imaging. Additionally, the bile duct and gastric lymph ducts and nodes were visualized. A positive correlation was found between the time to peak FI in the ischemic bowel loop and the corresponding capillary lactate levels (rho 0.59, p < 0.001).

CONCLUSION

In this study, we successfully demonstrated the simultaneous multipurpose IRDye® 800BK applicability during laparoscopic surgery. This fluorophore has the potential to become a powerful and versatile image-guided surgery tool.

Для цитирования: Al-Taher Mahdi, Barberio Manuel, Felli Eric, Agnus Vincent, Ashoka Anila Hoskere, Gioux Sylvain, Klymchenko Andrey, Bouvy Nicole, Stassen Laurents, Marescaux Jacques, Diana Michele. Simultaneous multipurpose fluorescence imaging with IRDye® 800BK during laparoscopic surgery.. Surgical endoscopy. 2020. DOI: 10.1007/s00464-020-07931-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.