MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0973-1482.187284

Медицинская библиотека · Journal of cancer research and therapeutics · 2018

Evaluation of the photon dose calculation accuracy in radiation therapy of malignant pleural mesothelioma.

Mahmoudi Golshan, Farhood Bagher, Shokrani Parvaneh, Amouheidari Alireza, Atarod Maryam

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Photon dose distribution of malignant pleural mesothelioma (MPM) in matched photon-electron technique is influenced by media inhomogeneity, lateral electronic disequilibrium at interfaces and narrow field. These may influence the dose calculation accuracy, calculated by treatment planning systems (TPS). This study aimed to evaluate the dose calculation accuracy of TiGRT TPS in radiation therapy of MPM.

MATERIALS AND

METHODS

18 MV photon beams of ONCOR Siemens linear accelerator was simulated using EGSnrc Monte Carlo (MC) code. Data of four patients were used to compare TPS and MC results in different regions included: Open and in-field, under shied and out of field regions.

RESULTS

Compared to MC results, the TPS overestimated the pleura dose coverage (90% of prescribed dose) about 3-12 mm, and also it overestimated the dose in under the shielded regions of lung (4-74%). While the TPS underestimated the dose profile width about 1-16 mm in low dose region (<50% prescribed dose) as well as the out of field region dose (4-100%).

CONCLUSIONS

Results showed that TPS underestimated the dose in out of field and overestimated the dose in under the shielded regions. Unlike MC measurements, TPS calculation showed adequate pleural dose coverage. Based on the results, MC calculation can be used in matched photon-electron beam radiation therapy of MPM to modify the TPS photon dose calculations in the presence of heterogeneity, interfaces, and shield in MPM radiotherapy.

Для цитирования: Mahmoudi Golshan, Farhood Bagher, Shokrani Parvaneh, Amouheidari Alireza, Atarod Maryam. Evaluation of the photon dose calculation accuracy in radiation therapy of malignant pleural mesothelioma.. Journal of cancer research and therapeutics. 2018. DOI: 10.4103/0973-1482.187284.