MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/icvts/ivy254

Медицинская библиотека · Interactive cardiovascular and thoracic surgery · 2019

Diode-pumped neodymium:yttrium aluminum garnet laser effects on the visceral pleura in an ex vivo porcine lung model†.

Bölükbas Servet, Greve Thorsten, Biancosino Christian, Eberlein Michael, Schumacher Sarah, Gödde Daniel, Störkel Stephan, Redwan Bassam

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Resection of tumour spread on a very thin visceral pleura might be challenging, and collateral damage to the lung parenchyma might occur. We aimed to develop an operative technique, which might facilitate the parenchyma-sparing destruction of the visceral pleura. This experimental work investigated the effects of a neodymium:yttrium aluminum garnet (Nd:YAG) laser on the visceral pleura in an ex vivo porcine lung model.

METHODS

We used a diode-pumped Nd:YAG laser (Limax® 120, KLS Martin, Tuttlingen, Germany) to investigate the effects on the visceral pleural in 20 porcine lungs. The laser was applied on a standardized length in 4 different settings: Group I (80 W, 6 s), Group II (80 W, 12 s), Group III (120 W, 6 s) and Group IV (120 W, 12 s). All specimens were analysed histologically.

RESULTS

The mean thickness of the visceral pleura was 81 ± 10 μm. Increasing power levels and longer application duration resulted in significantly enhanced laser destruction effects. The mean depths of the carbonization zone were 142 ± 42 µm, 378 ± 137 µm, 607 ± 155 µm and 1371 ± 271 μm for Groups I-IV, respectively (P < 0.001). The ratio of carbonization zone to pleural thickness was measured for each section (C/P ratio) to quantify the thermal effects. The corresponding C/P ratio for Groups I-IV were 1.72 ± 0.55, 4.98 ± 1.96, 7.11 ± 1.61 and 17.35 ± 4.35, respectively (P < 0.001).

CONCLUSIONS

Our study showed that increasing power levels and application duration of the laser lead to a significantly increased carbonization and destruction zones. Further in vivo human studies should evaluate the feasibility of laser application for a potential translational relevance for human use.

Для цитирования: Bölükbas Servet, Greve Thorsten, Biancosino Christian, Eberlein Michael, Schumacher Sarah, Gödde Daniel, Störkel Stephan, Redwan Bassam. Diode-pumped neodymium:yttrium aluminum garnet laser effects on the visceral pleura in an ex vivo porcine lung model†.. Interactive cardiovascular and thoracic surgery. 2019. DOI: 10.1093/icvts/ivy254.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.