MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiol.2017170347

Медицинская библиотека · Radiology · 2017

Feasibility and Safety of Intrathoracic Biopsy and Repeat Biopsy for Evaluation of Programmed Cell Death Ligand-1 Expression for Immunotherapy in Non-Small Cell Lung Cancer.

Tsai Emily B, Pomykala Kelsey, Ruchalski Kathleen, Genshaft Scott, Abtin Fereidoun, Gutierrez Antonio, Kim Hyun J, Li Alice, Adame Carlos, Jalalian Ashkan, Wolf Brian, Garon Edward B, Goldman Jonathan W, Suh Robert

СтатьяПеревод пока не подготовлен

Аннотация

Purpose To determine feasibility and safety of biopsy and repeat biopsy for assessment of programmed cell death ligand-1 (PD-L1) status. Materials and Methods This retrospective analysis reviewed 101 patients who underwent transthoracic core needle biopsy for the KEYNOTE-001 (MK-3475) clinical trial of pembrolizumab, an antiprogrammed cell death-1 therapy for non-small cell lung cancer, from May 2012 to September 2014. Sixty-one male patients (mean age, 66.1 years; range 36-83 years) and 40 female patients (mean age, 66.8 years; age range, 36-90 years) were included. Data collected included population characteristics, treatment history, target location, size, and depth from pleura. Adequacy of the tissue sample for diagnostic testing and rates of biopsy-related complications were assessed. Statistical analysis was performed by using univariate and multivariate generalized linear models to determine significant risk factors for biopsy complications. Results A total of 110 intrathoracic biopsies were performed, and 101 (91.8%) were performed as repeat biopsies subsequent to a previous percutaneous or bronchoscopic biopsy or previous surgical biopsy or resection. More than 84.5% (93 of 110) of biopsies were performed in patients who had undergone previous local or systemic therapy. Specimens were adequate for evaluation of PD-L1 expression in 96.4% of biopsies. Procedure-related complications occurred in 28 biopsies (25.4%); pneumothorax was most common (22.7%). Overall mean number of core needle biopsy samples obtained was 7.9 samples. Conclusion Image-guided transthoracic core needle biopsy is an effective method for obtaining tissue for PD-L1 expression analysis. © RSNA, 2017.

Для цитирования: Tsai Emily B, Pomykala Kelsey, Ruchalski Kathleen, Genshaft Scott, Abtin Fereidoun, Gutierrez Antonio, Kim Hyun J, Li Alice, Adame Carlos, Jalalian Ashkan, Wolf Brian, Garon Edward B, Goldman Jonathan W, Suh Robert. Feasibility and Safety of Intrathoracic Biopsy and Repeat Biopsy for Evaluation of Programmed Cell Death Ligand-1 Expression for Immunotherapy in Non-Small Cell Lung Cancer.. Radiology. 2017. DOI: 10.1148/radiol.2017170347.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.