MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0886-3350(03)00240-2

Медицинская библиотека · Journal of cataract and refractive surgery · 2003

High-frequency ultrasound biomicroscopy of silicone posterior chamber phakic intraocular lens for hyperopia.

García-Feijoó Julián, Hernández-Matamoros José L, Castillo-Gómez Alfredo, Lázaro Carlos, Méndez-Hernández Carmen, Martín Teresa, Martínez de la Casa J M, García-Sánchez Julián

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To study the intraocular position and anatomic relationships of the PRL-III phakic refractive lens (PRL), a posterior chamber phakic intraocular lens (PCP IOL), in cases of hyperopia using ultrasound biomicroscopy (UBM).

SETTING

Centro Oftalmológico Real Vision, Madrid, Spain, and Instituto de Investigaciones Oftalmológicas Ramón Castroviejo, Universidad Complutense, Madrid, Spain.

METHODS

Eleven phakic hyperopic eyes of 6 patients who had PRL implantation were examined by UBM 1 month after surgery. The PRL position, PRL-crystalline lens peripheral distance, and central distance between the corneal endothelium and the PRL were measured.

RESULTS

Eight eyes had both haptics on the zonule, 2 had 1 haptic in the sulcus and 1 on the zonule, and 1 had 1 haptic in the sulcus and the other in the ciliary body. The mean PCP IOL-crystalline lens peripheral distance in the minor axis was 239.7 microm +/- 179.4 (SD) and the mean PCP IOL-endothelium central distance, 2146.98 +/- 219.6 microm. Contact between the PCP IOL and crystalline lens was observed in 1 eye.

CONCLUSIONS

In this study of hyperopic eyes, the PRL was located on the zonule in most cases. However, the location of the haptics in the sulcus and contact between the PCP IOL and the crystalline lens that occurred in some cases suggest further study of possible long-term complications is needed.

Для цитирования: García-Feijoó Julián, Hernández-Matamoros José L, Castillo-Gómez Alfredo, Lázaro Carlos, Méndez-Hernández Carmen, Martín Teresa, Martínez de la Casa J M, García-Sánchez Julián. High-frequency ultrasound biomicroscopy of silicone posterior chamber phakic intraocular lens for hyperopia.. Journal of cataract and refractive surgery. 2003. DOI: 10.1016/s0886-3350(03)00240-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.