Ultrasound biomicroscopy of silicone posterior chamber phakic intraocular lens for myopia.

García-Feijoó Julián, Hernández-Matamoros José L, Méndez-Hernández Carmen, Castillo-Gómez Alfredo, Lázaro Carlos, Martín Teresa, Cuiña-Sardiña Ricardo, García-Sánchez Julián

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To study the intraocular position and anatomic relationships of PRL-III (phakic refractive lens) (PRL) posterior chamber phakic intraocular lens (PCP IOL) for high myopia using ultrasound biomicroscopy (UBM).

SETTING

Centro Oftalmológico Real Vision, and Instituto de Investigaciones Oftalmológicas Ramón Castroviejo, Universidad Complutense de Madrid, Madrid, Spain.

METHODS

Sixteen phakic myopic eyes that had had PRL implantation were examined by UBM 1 month after surgery. The PRL position, PRL-crystalline lens peripheral distance, and central distance between the corneal endothelium and the PRL were measured.

RESULTS

Both haptics were on the zonule in 6 eyes, in the ciliary sulcus in 5 eyes, and impacted in the ciliary body in 1 eye. In the 4 remaining eyes, the haptics were in mixed positions. The mean PCP IOL crystalline lens peripheral distance in the minor axis was 588.1 microm +/- 232.5 (SD), and the mean PCP IOL-endothelium central distance was 2082.8 +/- 277.6 microm.

CONCLUSIONS

Phakic refractive lens implantation should be done carefully because of the sulcus location of the haptics in many cases. This, with the iris-PRL contact, suggests caution for the long-term outcome.

Для цитирования: García-Feijoó Julián, Hernández-Matamoros José L, Méndez-Hernández Carmen, Castillo-Gómez Alfredo, Lázaro Carlos, Martín Teresa, Cuiña-Sardiña Ricardo, García-Sánchez Julián. Ultrasound biomicroscopy of silicone posterior chamber phakic intraocular lens for myopia.. Journal of cataract and refractive surgery. 2003. DOI: 10.1016/s0886-3350(03)00239-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.