Air-filled vs water-filled intragastric balloon: a prospective randomized study.

Giardiello Cristiano, Borrelli Alessandro, Silvestri Eufemia, Antognozzi Valentina, Iodice Giuseppe, Lorenzo Michele

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The positioning of an intragastric saline-filled balloon has been developed as temporary and reversible therapeutic option for treatment of morbid obesity. Recently, an air-filled balloon was also developed. The aim of this study is to prospectively compare these two devices in terms of weight loss parameters, safety, and tolerance.

METHODS

Sixty patients were randomized into two groups: group A (Bioenterics Intragastric Balloon-BIB; n = 30; 20 F/10 M, mean age 36.7 ± 10.9; mean BMI 46.5 ± 5.9) and group B (Endobag-Heliosphere; n = 30; 20 F/10 M, mean age 37.8 ± 10.6; mean BMI 46.1 ± 5.6). All patients of both groups were sedated with midazolam (5 mg) + Propofol (2 mg/kg i.v.). The Heliosphere Bag was air-filled with 950 ml while BIB® was inflated with 500 ml of saline and 10 ml of methylene blue. Percentage of excess weight loss (%EWL) and body mass index (BMI) were evaluated. Student t test, Fisher exact test, and χ(2) test were used for statistical analysis.

RESULTS

Similar weight loss parameters were observed in patients treated with liquid or air-filled balloon at time of removal: mean BMI was 40.8 ± 6.2 and 41.9 ± 6.5(p = ns), and mean %EWL was 20 ± 12 and 18 ± 14 (p = ns) in groups A and B, respectively. Significant longer extraction time, with high patient discomfort, was observed in group B due to difficult passage through the cardia and the lower pharynx.

CONCLUSIONS

Air-filled balloon can be another valid therapeutic option in the temporary treatment of obesity, but at this time, the quality of the device must be improved to ameliorate the patient compliance at removal and avoid the spontaneous deflations.

Для цитирования: Giardiello Cristiano, Borrelli Alessandro, Silvestri Eufemia, Antognozzi Valentina, Iodice Giuseppe, Lorenzo Michele. Air-filled vs water-filled intragastric balloon: a prospective randomized study.. Obesity surgery. 2012. DOI: 10.1007/s11695-012-0786-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.