PURPOSE/

INTRODUCTION

To assess the variation in the doses received by the organs at risk (OARs) that can occur during treatment planning of cervical cancer by image-based brachytherapy.

METHODS AND MATERIALS: After intracavitary application, two sets of images-CT and MRI-were obtained. The two sets of images were fused together with respect to the applicator. Contouring was done separately on CT and MR images. Dose received by the OARs on CT images with respect to the plans made on the MR images was estimated and compared with those on the MR images.

RESULTS

Although there was always a difference between the dose received by the OARs based on the CT and MRI contours, it was not significant for the bladder and rectum; 2 cc doses differed by 0.49 Gy (±0.44) p = 0.28 for the bladder and 0.30 Gy (±0.29) p = 0.16 for the rectum. The 1 cc and 0.1 cc differences were also not significant. However for the sigmoid colon, there was significant intrafraction variation in the 2 cc doses 0.61 (±0.6) p = 0.001, 1 cc doses 0.73 (±0.67) Gy p = 0.00, and 0.1 cc dose 0.97 (±0.93) Gy p = 0.009.

CONCLUSIONS

The variation in the doses to the OARs must be considered while weighing target coverage against overdose to the OARs. Although not significant for the bladder and rectum, it was significant for the sigmoid colon. Estimated doses to OARs on the planning system may not be the same dose delivered at the time of treatment.

Для цитирования: Simha Vijai, Patel Firuza Darius, Sharma Suresh Chander, Rai Bhavana, Oinam Arun Singh, krishnatry Rahul, Dhanireddy Bhaswanth. Evaluation of intrafraction motion of the organs at risk in image-based brachytherapy of cervical cancer.. Brachytherapy. 2014. DOI: 10.1016/j.brachy.2014.05.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.