MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0284185114533683

Медицинская библиотека · Acta radiologica (Stockholm, Sweden : 1987) · 2014

Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study.

Lambert Lukas, Danes Jan, Jahoda Jiri, Masek Martin, Lisy Jiri, Ourednicek Petr

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Computed tomography (CT) colonography is a well established modality for the examination of symptomatic patients as well as in screening. Recent technical advances in improving image quality by iterative reconstruction contribute to the reduction of the radiation dose which is a major concern in CT imaging.

PURPOSE: To evaluate image quality of ultralow-dose submilisievert CT colonography using hybrid iterative reconstruction technique.

MATERIAL AND

METHODS

Sixteen patients underwent contrast-enhanced CT colonography with standard protocol in supine position and ultralow-dose protocol in prone position. Ultralow-dose datasets were reconstructed with filtered back projection and an advanced hybrid iterative reconstruction technique. Two radiologists independently evaluated 96 colonic segments for image quality in the endoluminal view and axial thin sections. Colonic distension, smoothness of colonic wall and distortion of folds in the endoluminal view, sharpness of colonic wall delineation, perceived image noise, and presence of photon starvation artifact were rated on a five-point scale. Intraluminal noise expressed as standard deviation of Hounsfield density was measured in all segments.

RESULTS

The mean radiation dose was 0.42 mSv and 5.48 mSv in prone and supine scans, respectively. All distended segments were rated evaluable in standard dose and ultralow-dose series reconstructed with the iterative reconstruction technique, whereas in 61% segments image quality was rated poor or unacceptable in ultralow-dose series where filtered back projection was used with worst ratings in the rectum and the sigmoid colon.

CONCLUSION

This pilot study shows that iterative reconstruction technique is a feasible method to decrease the radiation dose from CT colonography for both positions below 1mSv. Further investigations of larger scale need to be done to clarify, whether such a low radiation dose would influence the detection of polyps.

Для цитирования: Lambert Lukas, Danes Jan, Jahoda Jiri, Masek Martin, Lisy Jiri, Ourednicek Petr. Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study.. Acta radiologica (Stockholm, Sweden : 1987). 2014. DOI: 10.1177/0284185114533683.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.