MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.brachy.2014.02.003

Медицинская библиотека · Brachytherapy · 2014

Proof of principle: Applicator-guided stereotactic IMRT boost in combination with 3D MRI-based brachytherapy in locally advanced cervical cancer.

Assenholt Marianne S, Vestergaard Anne, Kallehauge Jesper F, Mohamed Sandy, Nielsen Søren K, Petersen Jørgen B, Fokdal Lars, Lindegaard Jacob C, Tanderup Kari

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To describe a new technique involving high-precision stereotactic intensity-modulated radiation therapy (IMRT) boost in combination with intracavitary-interstitial (IC-IS) brachytherapy (BT) in cervical tumors that cannot be sufficiently covered by IC-IS-BT due to extensive residual disease and/or difficult topography at the time of BT.

METHODS AND MATERIALS: Three patients with stage IIIB-IVA cervical cancer had significant residual disease at the time of BT. MRI-guided IC-IS-BT (pulsed-dose rate) was combined with a stereotactic IMRT boost guided according to the BT applicator in situ, using cone beam CT. The planning aim dose (total external beam radiotherapy and BT) for the high-risk clinical target volume (HR-CTV) was D90 >70-85 Gy, whereas constraints for organs at risk were D2cm3 <70 Gy for rectum, sigmoid, and bowel and <90 Gy for bladder in terms of equivalent total dose in 2 Gy fractions. An IMRT boost adapted to the BT dose distribution was optimized to target the regions poorly covered by BT.

RESULTS

HR-CTV doses of D90 >81 Gy were obtained in the central HR-CTV and D90 >69 Gy in the distal regions of HR-CTV. Image-guided set up of the IMRT boost with the applicator in situ was feasible. The dose plans were robust to intra-fraction uncertainties of 3 mm. Local control with acceptable morbidity was obtained at a followup of 3, 2.5, and 1 year, respectively.

CONCLUSIONS

The combination of MRI-guided BT with an applicator-guided stereotactic IMRT boost is feasible. This technique seems to be useful in the few cases where HR-CTV coverage cannot be obtained even with IS-IC-BT.

Для цитирования: Assenholt Marianne S, Vestergaard Anne, Kallehauge Jesper F, Mohamed Sandy, Nielsen Søren K, Petersen Jørgen B, Fokdal Lars, Lindegaard Jacob C, Tanderup Kari. Proof of principle: Applicator-guided stereotactic IMRT boost in combination with 3D MRI-based brachytherapy in locally advanced cervical cancer.. Brachytherapy. 2014. DOI: 10.1016/j.brachy.2014.02.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.