MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-025-05137-x

Медицинская библиотека · Abdominal radiology (New York) · 2025

Quantification of hepatic steatosis on post-contrast computed tomography scans using artificial intelligence tools.

Derstine Brian A, Holcombe Sven A, Chen Vincent L, Pai Manjunath P, Sullivan June A, Wang Stewart C, Su Grace L

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Early detection of steatotic liver disease (SLD) is critically important. In clinical practice, hepatic steatosis is frequently diagnosed using computed tomography (CT) performed for unrelated clinical indications. An equation for estimating magnetic resonance proton density fat fraction (MR-PDFF) using liver attenuation on non-contrast CT exists, but no equivalent equation exists for post-contrast CT. We sought to (1) determine whether an automated workflow can accurately measure liver attenuation, (2) validate previously identified optimal thresholds for liver or liver-spleen attenuation in post-contrast studies, and (3) develop a method for estimating MR-PDFF (FF) on post-contrast CT.

METHODS

The fully automated TotalSegmentator 'total' machine learning model was used to segment 3D liver and spleen from non-contrast and post-contrast CT scans. Mean attenuation was extracted from liver (L) and spleen (S) volumes and from manually placed regions of interest (ROIs) in multi-phase CT scans of two cohorts: derivation (n = 1740) and external validation (n = 1044). Non-linear regression was used to determine the optimal coefficients for three phase-specific (arterial, venous, delayed) increasing exponential decay equations relating post-contrast L to non-contrast L. MR-PDFF was estimated from non-contrast CT and used as the reference standard.

RESULTS

The mean attenuation for manual ROIs versus automated volumes were nearly perfectly correlated for both liver and spleen (r > .96, p < .001). For moderate-to-severe steatosis (L < 40 HU), the density of the liver (L) alone was a better classifier than either liver-spleen difference (L-S) or ratio (L/S) on post-contrast CTs. Fat fraction calculated using a corrected post-contrast liver attenuation measure agreed with non-contrast FF > 15% in both the derivation and external validation cohort, with AUROC between 0.92 and 0.97 on arterial, venous, and delayed phases.

CONCLUSION

Automated volumetric mean attenuation of liver and spleen can be used instead of manually placed ROIs for liver fat assessments. Liver attenuation alone in post-contrast phases can be used to assess the presence of moderate-to-severe hepatic steatosis. Correction equations for liver attenuation on post-contrast phase CT scans enable reasonable quantification of liver steatosis, providing potential opportunities for utilizing clinical scans to develop large scale screening or studies in SLD.

Для цитирования: Derstine Brian A, Holcombe Sven A, Chen Vincent L, Pai Manjunath P, Sullivan June A, Wang Stewart C, Su Grace L. Quantification of hepatic steatosis on post-contrast computed tomography scans using artificial intelligence tools.. Abdominal radiology (New York). 2025. DOI: 10.1007/s00261-025-05137-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.