MedElevator Войти в исследования
← Поиск публикаций

DOI 10.11607/jomi.5290

Медицинская библиотека · The International journal of oral & maxillofacial implants · 2017

Association Between Bone Graft Volume and Maxillary Sinus Membrane Elevation Height.

Sonoda Tetsuya, Harada Takehiro, Yamamichi Nobuyuki, Monje Alberto, Wang Hom-Lay

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Maxillary sinus augmentation via crestal approach has been advocated as an alternative approach for sinus membrane elevation. Presently, no study has examined the relationship between the amount of bone grafting material placed and the final sinus membrane elevation height. Therefore, the present study was aimed at investigating the extent of sinus membrane elevation height depending on the amount of bone grafting material inserted as well as three-dimensionally assessing the likelihood of membrane perforation during membrane elevation.

MATERIALS AND

METHODS

A total of 34 subjects (16 females and 18 males) with 61 crestal sinus elevation sites were recruited. The following changes in elevated sinus membrane area were recorded: vertical elevation height (VEH), buccopalatal elevation (BPE), and mesiodistal elevation (MDE). Cone beam computed tomography (CBCT) was used to measure the elevated height of the maxillary sinus floor at the initial examination, during surgery, and immediately after surgery. In addition, the VEH:BPE and VEH:MDE ratios at each site were calculated using CBCT to determine the probability of sinus membrane perforation.

RESULTS

In average, 0.1 mL of bone graft material placed elevated VEH an average of 3.5 mm, while 0.2 mL and 0.3 mL of graft placed elevated VEH 5 mm and 6 mm, respectively. Furthermore, it was demonstrated that the VEH:BPE and VEH:MDE ratios play a determinant role on membrane integrity. As such, a ratio greater than 1.0 may jeopardize membrane integrity, while a ratio ≤ 0.8 might represent a lower risk of membrane perforation.

CONCLUSION

An initial 0.1 mL of bone material filling can elevate sinus membrane vertically by 3.5 mm. To avoid sinus membrane perforation, a VEH:BPE or VEH:MDE ratio of ≤ 0.8 should be obtained.

Для цитирования: Sonoda Tetsuya, Harada Takehiro, Yamamichi Nobuyuki, Monje Alberto, Wang Hom-Lay. Association Between Bone Graft Volume and Maxillary Sinus Membrane Elevation Height.. The International journal of oral & maxillofacial implants. 2017. DOI: 10.11607/jomi.5290.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.