MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12659/pjr.899221

Медицинская библиотека · Polish journal of radiology · 2016

Evaluation of the Posterior Superior Alveolar Artery Using Cone Beam Computed Tomography.

Pandharbale Atul A, Gadgil Rajeev M, Bhoosreddy Ajay R, Kunte Varun R, Ahire Bhushan S, Shinde Manila R, Joshi Sidharth S

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Maxillary posterior tooth region is an important area with respect to periapical surgery, implant placement, and sinus lifts. Posterior superior alveolar artery (PSAA) is located on the lateral wall of maxillary sinus and may become injured during such surgical procedures. Therefore, knowledge of the subject is essential to a clinician. The goal was to determine the anatomical relationship of posterior superior alveolar artery to the floor of maxillary sinus and alveolar crest. In our study we attempted to present the locations and course of posterior superior alveolar artery (PSAA) using cone beam computed tomography (CBCT) imaging.

MATERIAL/

METHODS

CBCT scans of 50 patients (30 males, 20 females) who had undergone computed tomography imaging were analyzed. We assessed the visibility and location of vascular canal/notch of posterior superior alveolar artery on cross sectional images and measured the distances from lower margin to the floor of maxillary sinus and alveolar crest in the 1st molar and 2nd molar regions. Unpaired t-test was carried out in the analysis to determine the level of significance.

RESULTS

Maxillary PSAA was visualized in 36 patients (70%). Mean diameter of the vessel was 0.63 mm. Mean distance between PSAA and alveolar crest was the shortest in the 2nd molar region. The mean distance between PSAA and floor of maxillary sinus was 9.96 mm.

CONCLUSIONS

Periapical surgeries, implants and maxillary sinus lift are performed on routine basis. PSAA is an important structure in the posterior maxillary region; the clinician should be aware of its location and course. CBCT is an excellent tool to localize the PSAA because of it provides finer details at low exposure and less radiation. It should be recommended in clinical practices.

Для цитирования: Pandharbale Atul A, Gadgil Rajeev M, Bhoosreddy Ajay R, Kunte Varun R, Ahire Bhushan S, Shinde Manila R, Joshi Sidharth S. Evaluation of the Posterior Superior Alveolar Artery Using Cone Beam Computed Tomography.. Polish journal of radiology. 2016. DOI: 10.12659/pjr.899221.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.