International journal of implant dentistry · 2016
Long-term radiographic assessment of maxillary sinus floor augmentation using beta-tricalcium phosphate: analysis by cone-beam computed tomography.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Okada Tsuneji, Kanai Toru, Tachikawa Noriko, Munakata Motohiro, Kasugai Shohei
Аннотация
BACKGROUND: The long-term stability of maxillary sinus floor augmentation with β-TCP remains largely unknown. We report the long-term assessment of volumetric changes in maxillary sinus floor augmentation with β-TCP by cone-beam computed tomography (CBCT).
METHODS: The subjects included 30 patients who underwent maxillary sinus floor augmentation using β-TCP and 58 implant placement for unilateral maxillary defect, simultaneously. Volumetric changes in β-TCP and the height of peri-implant bone were analyzed by CBCT.
RESULTS: In all patients, the mean volume of the grafted bone decreased from immediately after implant placement to 6 months after implant placement (75.6 % reduction rate); it decreased further at 2.5 years after implant placement (54.9 % reduction rate). The mean of the height from the implant tip to the maxillary sinus floor was 2.00 ± 1.51 mm, 0.73 ± 1.33 mm, and -0.72 ± 1.11 mm immediately, 6 months, and 2.5 years after implant placement, respectively. The implant tip protruded beyond the maxillary sinus floor in approximately 70 % of the implants (41/58 implants) at 2.5 years after surgery. During the observation period, the implant survival rate was 100 %.
CONCLUSIONS: The radiographic analysis by CBCT is considerably more advanced than previous radiographic examinations. Although maxillary sinus pneumatization continues to progress ≥1 year after maxillary sinus floor augmentation with β-TCP, it stabilizes 3 years after surgery.
METHODS: The subjects included 30 patients who underwent maxillary sinus floor augmentation using β-TCP and 58 implant placement for unilateral maxillary defect, simultaneously. Volumetric changes in β-TCP and the height of peri-implant bone were analyzed by CBCT.
RESULTS: In all patients, the mean volume of the grafted bone decreased from immediately after implant placement to 6 months after implant placement (75.6 % reduction rate); it decreased further at 2.5 years after implant placement (54.9 % reduction rate). The mean of the height from the implant tip to the maxillary sinus floor was 2.00 ± 1.51 mm, 0.73 ± 1.33 mm, and -0.72 ± 1.11 mm immediately, 6 months, and 2.5 years after implant placement, respectively. The implant tip protruded beyond the maxillary sinus floor in approximately 70 % of the implants (41/58 implants) at 2.5 years after surgery. During the observation period, the implant survival rate was 100 %.
CONCLUSIONS: The radiographic analysis by CBCT is considerably more advanced than previous radiographic examinations. Although maxillary sinus pneumatization continues to progress ≥1 year after maxillary sinus floor augmentation with β-TCP, it stabilizes 3 years after surgery.