MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1902/jop.2016.160337

Медицинская библиотека · Journal of periodontology · 2016

Influence of Sinus Floor Configuration on Grafted Bone Remodeling After Osteotome Sinus Floor Elevation.

Chen Hsuan-Hung, Lin Yi-Chun, Lee Shyh-Yuan, Chang Lien-Yu, Chen Bor-Jian, Lai Yu-Lin

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

This study investigates influence of the sinus floor configuration on dimensional stability of grafted bone height after the osteotome sinus grafting procedure.

METHODS

Forty single-tooth dental implants inserted after placement of bioglass and/or allograft into the sinus area using an osteotome technique in 37 patients were evaluated in this retrospective study. Periapical radiographs were taken using the long-cone technique before and after implant placement. Specifically, radiographic measurements of grafted bone height at the mesial and distal side of each implant were taken, and the sinus floor configuration was classified into concave, angle, and flat according to the sinus floor profile at the implant site. Furthermore, the intruding angle, defined as the angle between the implant axis and sinus floor, was measured.

RESULTS

All implants were clinically stable during a mean follow-up period of 39.2 months. Mean initial gain of sinus grafted bone height was 7.0 ± 1.9 mm, and later it was reduced to 4.6 ± 1.9 mm at follow-up (P <0.001). A greater reduction in grafted bone height was revealed in the flat sinus group compared with the concave group (P <0.001). Results from the linear regression showed larger intruding angles were statistically significantly associated with a greater reduction in grafted bone height (r2 = 0.55, P <0.001).

CONCLUSION

All bioglass and/or allograft placed in the maxillary sinus after the osteotome technique underwent remodeling and shrinkage; however, the outcome of the procedure was more predictable in sinuses with a concave floor and small implant-intruding angles.

Для цитирования: Chen Hsuan-Hung, Lin Yi-Chun, Lee Shyh-Yuan, Chang Lien-Yu, Chen Bor-Jian, Lai Yu-Lin. Influence of Sinus Floor Configuration on Grafted Bone Remodeling After Osteotome Sinus Floor Elevation.. Journal of periodontology. 2016. DOI: 10.1902/jop.2016.160337.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.