Surgical Microanatomy of Lower Eyelid Tarsal Ectropion Repair With a Putterman Ptosis Clamp.

Jones Scott T, Aakalu Vinay K, Lin Amy Y, Perez Catherine, Epstein Gil, Putterman Allen M, Setabutr Pete

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To examine the changes in microscopic anatomy of the lower eyelid tarsal ectropion repair with the Putterman ptosis clamp and better understand the anatomical changes associated with the eyelid malposition correction.

METHODS

Ten orbits from 5 fresh frozen cadaver heads, ranging in age from 53 to 77 years, were used for the dissection. For each head, a Putterman clamp tarsal ectropion repair was performed on one side, while the contralateral unoperated orbit served as a control. After performing the procedure, both orbits were exenterated and they, along with the resected specimens, were studied microscopically using Verhoeff-Masson trichrome and hematoxylin-eosin stains.

RESULTS

Conjunctiva, capsulopalpebral fascia, and smooth muscle were present on all tissue specimens incarcerated within the ptosis clamp. Tarsus was present in one specimen. There was a shortening of the posterior lamella of the eyelid with advancement of the capsulopalpebral fascia on all operated specimens when compared with controls.

CONCLUSION

The Putterman clamp ectropion repair works by shortening the posterior lamella of the eyelid and advancing the lower eyelid retractors superiorly. This advancement tightens the lower eyelid retractors and thus stabilizes the eyelid in a more vertical position. In addition to a lateral tendon tuck as described in the original article to tighten horizontal eyelid laxity, this procedure addresses both vertical and horizontal laxity of tarsal ectropion.

Для цитирования: Jones Scott T, Aakalu Vinay K, Lin Amy Y, Perez Catherine, Epstein Gil, Putterman Allen M, Setabutr Pete. Surgical Microanatomy of Lower Eyelid Tarsal Ectropion Repair With a Putterman Ptosis Clamp.. Ophthalmic plastic and reconstructive surgery. 2017. DOI: 10.1097/iop.0000000000000737.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.