MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.xfre.2023.05.004

Медицинская библиотека · F&S reports · 2023

A risk factor profile for placenta accreta spectrum in pregnancies conceived with assisted reproductive technology.

Carusi Daniela A, Gopal Daksha, Cabral Howard J, Racowsky Catherine, Stern Judy E

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To identify independent risk factors for placenta accreta spectrum among pregnancies conceived with assisted reproductive technology.

DESIGN

Retrospective cohort study.

SETTING

Tertiary hospital.

PATIENTS: Individuals who conceived with assisted reproductive technology and reached 20 weeks' gestation or later from 2011 to 2017.

INTERVENTIONS: Patient and cycle data was abstracted from hospital records and supplemented with state-level data. Poisson regression was used for multivariate analyses and reported as adjusted relative risks (aRR).

MAIN OUTCOME MEASURES: Clinical or histologic placenta accreta spectrum.

RESULTS

Of 1,975 qualifying pregnancies, 44 (2.3%) met criteria for accreta spectrum at delivery. In the multivariate model, significant risk factors included low-lying placenta at delivery (aRR, 15.44; 95% CI 7.76-30.72), uterine factor infertility or prior uterine surgery (aRR, 4.68; 95% CI, 2.72-8.05), initial low-lying placentation that resolved (aRR, 3.83; 95% CI, 1.90-7.73), and use of frozen embryos (aRR, 3.02; 95% CI, 1.66-5.48). When the fresh vs frozen variable was replaced with controlled ovarian hyperstimulation, the final model did not change (aRR, 2.40 for unstimulated cycles, 95% CI, 1.32-4.38). With frozen transfers, the accreta rate was 16% when the endometrial thickness was < 6mm vs 3.8% with thicker endometrium (P=.02).

CONCLUSIONS

Among pregnancies conceived with assisted reproductive technology, accreta spectrum is associated with low placental implantation (even when resolved), uterine factor infertility and prior uterine surgery, and the use of frozen embryo transfer or unstimulated cycles.

Для цитирования: Carusi Daniela A, Gopal Daksha, Cabral Howard J, Racowsky Catherine, Stern Judy E. A risk factor profile for placenta accreta spectrum in pregnancies conceived with assisted reproductive technology.. F&S reports. 2023. DOI: 10.1016/j.xfre.2023.05.004.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.