MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000345865

Медицинская библиотека · Gynecologic and obstetric investigation · 2012

The use of a new gel foam for the evaluation of tubal patency.

Van Schoubroeck Dominique, Van den Bosch Thierry, Meuleman Christel, Tomassetti Carla, D'Hooghe Thomas, Timmerman Dirk

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: To evaluate the feasibility and the reliability of hysterosalpingo-foam sonography (HyFoSy) using gel foam in the assessment of tubal patency.

METHODS

Nonrandomized, observational, academic and single-center study of 20 women being investigated because of subfertility and scheduled for a laparoscopy with chromopertubation. A detailed description of HyFoSy with a newly developed gel foam is given in the way it proved to be most efficient in our hands. The results of HyFoSy are compared to the data regarding tubal patency testing during laparoscopy by chromopertubation.

RESULTS

All 20 HyFoSy were technically successful. Four of the 40 tubes, 1 right tube and 3 left tubes, were not patent at HyFoSy (3 tubes with proximal block and 1 tube with distal block). There was a 100% agreement between tubal patency data according to HyFoSy testing and laparoscopic chromopertubation testing.

CONCLUSION

HyFoSy is both feasible and accurate in the diagnosis of tubal patency.

Для цитирования: Van Schoubroeck Dominique, Van den Bosch Thierry, Meuleman Christel, Tomassetti Carla, D'Hooghe Thomas, Timmerman Dirk. The use of a new gel foam for the evaluation of tubal patency.. Gynecologic and obstetric investigation. 2012. DOI: 10.1159/000345865.