MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/21501351211027857

Медицинская библиотека · World journal for pediatric & congenital heart surgery · 2021

Long-Term Outcome Following Pulmonary Valve Replacement in Repaired Tetralogy of Fallot.

Al Mosa Alqasem Fuad H, Madathil Sreenath, Bernier Pierre-Luc, Tchervenkov Christo

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Late pulmonary valve replacement following repair of tetralogy of Fallot may become necessary in patients with chronic pulmonary insufficiency. There is limited information on the long-term outcome of these prostheses, which is the focus of this study.

METHODS

We conducted a retrospective study of patients with repaired tetralogy of Fallot who underwent pulmonary valve replacement from 1990 to 2015 in our institution. We investigated imaging and clinical parameters including mortality and late adverse events (reintervention [surgical or transcatheter]), infective endocarditis, or arrhythmias requiring device implantation or ablation.

RESULTS

There were 69 patients divided into 3 groups: Carpentier-Edwards (n = 14), Contegra (n = 40), and pulmonary homograft (n = 15). The mean age at the time of pulmonary valve replacement was 21 ± 12 years. The mean follow-up was 8.5 ± 4.7 years. The mean preoperative and postoperative right ventricular end-diastolic volume index was 210 ± 42 and 120 ± 24 mL/m2, respectively. There were no mortalities. Late adverse events were observed in 23 (33%) patients: 15 (22%) reintervention (surgical or transcatheter), 11 (16%) endocarditis, and 11 (16%) arrhythmias. Overall, 1-, 5-, and 10-year freedom from surgical reintervention was 98.5%, 93.6%, and 79.3%, respectively. The Contegra group had significantly higher pulmonary valve gradients, a higher risk of developing late adverse events compared to Carpentier-Edwards (P = .046) and pulmonary homograft (P = .055) in multivariate analysis and increased risk for reintervention in the univariate analysis (hazard ratio: 3.4; 95% CI: 0.92-13; P value.066).

CONCLUSION

Pulmonary valve replacement in patients with repaired tetralogy of Fallot has acceptable short- and intermediate-term outcomes. Contegra prosthesis had a higher risk of late adverse events with higher pulmonary valve gradients.

Для цитирования: Al Mosa Alqasem Fuad H, Madathil Sreenath, Bernier Pierre-Luc, Tchervenkov Christo. Long-Term Outcome Following Pulmonary Valve Replacement in Repaired Tetralogy of Fallot.. World journal for pediatric & congenital heart surgery. 2021. DOI: 10.1177/21501351211027857.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.