MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cnp.2020.02.003

Медицинская библиотека · Clinical neurophysiology practice · 2020

Interictal magnetoencephalography in parietal lobe epilepsy - Comparison of equivalent current dipole and beamformer (SAMepi) analysis.

Wilenius Juha, Lauronen Leena, Kirveskari Erika, Gaily Eija, Metsähonkala Liisa, Paetau Ritva

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate a novel analysis method (SAMepi) in the localization of interictal epileptiform magnetoencephalographic (MEG) activity in parietal lobe epilepsy (PLE) patients in comparison with equivalent current dipole (ECD) analysis.

METHODS

We analyzed the preoperative interictal MEG of 17 operated PLE patients utilizing visual analysis and: (1) ECD with a spherical conductor model; (2) ECD with a boundary element method (BEM) conductor model; and (3) SAMepi - a kurtosis beamformer method. Localization results were compared between the three methods, to the location of the resection and to the clinical outcome.

RESULTS

Fourteen patients had an epileptiform finding in the visual analysis; SAMepi detected spikes in 11 of them. A unifocal finding in both the ECD and in the SAMepi analysis was associated with a better chance of seizure-freedom (p = 0.02). There was no significant difference in the distances from the unifocal MEG localizations to the nearest border of the resection between the different analysis methods.

CONCLUSIONS

Localizations of unifocal interictal spikes detected by SAMepi did not significantly differ from the conventional ECD localizations.

SIGNIFICANCE: SAMepi - a novel semiautomatic analysis method - is useful in localizing interictal epileptiform MEG activity in the presurgical evaluation of parietal lobe epilepsy patients.

Для цитирования: Wilenius Juha, Lauronen Leena, Kirveskari Erika, Gaily Eija, Metsähonkala Liisa, Paetau Ritva. Interictal magnetoencephalography in parietal lobe epilepsy - Comparison of equivalent current dipole and beamformer (SAMepi) analysis.. Clinical neurophysiology practice. 2020. DOI: 10.1016/j.cnp.2020.02.003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.