MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5005/jp-journals-10071-24438

Медицинская библиотека · Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2023

Sonographic Optic Nerve Sheath Diameter as a Guide for Correction of Hyponatremia in the Emergency Department: A Cross-sectional Study.

Uttanganakam Sanjeed, Hansda Upendra, Sahoo Sangeeta, Shaji Ijas Muhammed, Guru Satyabrata, Topno Nitish, Sahoo Nishit Kumar

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Monitoring sodium levels during the correction of hyponatremia is essential. There is cell swelling due to the movement of water from extracellular to intracellular by osmotic effect in hyponatremia. The cellular swelling in a closed space causes increased intracranial pressure (ICP). The raised ICP correlates with the optic nerve sheath diameter (ONSD). So, the research question was whether the ONSD can be used as a guide for the correction of hyponatremia.

METHODS

It was a prospective observational study conducted on patients with serum sodium below 135 mEq/L presented to the emergency department (ED). The ONSD was measured at the time of presentation and discharge of the patient. The receiver operating characteristic curve (ROC) and area under the curve (AUC) were used to test the predictive ability of the ONSD to diagnose hyponatremia.

RESULTS

A total of 54 subjects were included in the study. The mean sodium level was 109.3 mEq/L at presentation. The mean ONSD on the right side was 6.24 ± 0.71 mm and on the left side was 6.26 ± 0.64 mm at presentation to ED. The mean ONSD on the right side was 5.81 ± 0.58 mm and on the left side was 5.79 ± 0.56 mm at discharge. The ONSD was not able to predict the sodium level measured both by laboratory and POC methods.

CONCLUSION

The ONSD failed to predict the sodium level in patients with hyponatremia during the correction. The change in ONSD did not correlate with the change in sodium level.

HOW TO CITE THIS ARTICLE: Uttanganakam S, Hansda U, Sahoo S, Shaji IM, Guru S, Topno N, et al. Sonographic Optic Nerve Sheath Diameter as a Guide for Correction of Hyponatremia in the Emergency Department: A Cross-sectional Study. Indian J Crit Care Med 2023;27(4):265-269.

Для цитирования: Uttanganakam Sanjeed, Hansda Upendra, Sahoo Sangeeta, Shaji Ijas Muhammed, Guru Satyabrata, Topno Nitish, Sahoo Nishit Kumar. Sonographic Optic Nerve Sheath Diameter as a Guide for Correction of Hyponatremia in the Emergency Department: A Cross-sectional Study.. Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine. 2023. DOI: 10.5005/jp-journals-10071-24438.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.