Audiology & neuro-otology · 2020
Audiological Findings in Patients with Vestibular Migraine and Migraine: History of Migraine May Be a Cause of Low-Tone Sudden Sensorineural Hearing Loss.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Xue Junfang, Ma Xin, Lin Yunjuan, Shan Haijun, Yu Lisheng
Аннотация
INTRODUCTION: The aim of this study was to investigate and compare the auditory findings in migraine, vestibular migraine (VM), and healthy controls.
METHODS: Twenty-eight migraine patients (56 ears), 18 VM (36 ears), and 25 healthy controls (50 ears) were included. Audiometry, speech discrimination scores, distortion product optoacoustic emission (DPOAE), and auditory brainstem response were tested.
RESULTS: The pure tone in the VM group showed higher thresholds at lower frequencies (250, 500, 1,000, 2,000 Hz) than the control group, with statistical differences observed (P250 Hz = 0.001, P500 Hz = 0.003, P1,000 Hz = 0.016, P2,000 Hz = 0.002). Compared with the healthy controls, the patients with VM had significantly lower amplitudes of DPOAE at 1 kHz (p < 0.001) and 2 kHz (p = 0.020), and the patients with migraine had lower amplitudes at 2 kHz (p = 0.042). Compared with the control group, the patients with migraine reported prolonged latency of wave V (p = 0.016) and IPL I-V (p = 0.003). The patients with VM had significant prolongation of IPL I-V (p = 0.024).
CONCLUSION: Not only the peripheral, but also the central auditory system was involved in patients with migraine and VM. In particular, lower frequencies of the auditory system were more likely to be involved in VM. The history of migraine may be a cause of low-tone sudden sensorineural hearing loss.
METHODS: Twenty-eight migraine patients (56 ears), 18 VM (36 ears), and 25 healthy controls (50 ears) were included. Audiometry, speech discrimination scores, distortion product optoacoustic emission (DPOAE), and auditory brainstem response were tested.
RESULTS: The pure tone in the VM group showed higher thresholds at lower frequencies (250, 500, 1,000, 2,000 Hz) than the control group, with statistical differences observed (P250 Hz = 0.001, P500 Hz = 0.003, P1,000 Hz = 0.016, P2,000 Hz = 0.002). Compared with the healthy controls, the patients with VM had significantly lower amplitudes of DPOAE at 1 kHz (p < 0.001) and 2 kHz (p = 0.020), and the patients with migraine had lower amplitudes at 2 kHz (p = 0.042). Compared with the control group, the patients with migraine reported prolonged latency of wave V (p = 0.016) and IPL I-V (p = 0.003). The patients with VM had significant prolongation of IPL I-V (p = 0.024).
CONCLUSION: Not only the peripheral, but also the central auditory system was involved in patients with migraine and VM. In particular, lower frequencies of the auditory system were more likely to be involved in VM. The history of migraine may be a cause of low-tone sudden sensorineural hearing loss.
Предметные рубрики MeSH
Acoustic Impedance TestsAdolescentAdultAudiometry, Pure-ToneAudiometry, SpeechCase-Control StudiesEvoked Potentials, Auditory, Brain StemFemaleHearing Loss, SensorineuralHearing Loss, SuddenHumansMaleMiddle AgedMigraine DisordersOtoacoustic Emissions, SpontaneousRisk FactorsSpeech Discrimination TestsVertigoYoung Adult