Patient-specific Effective Dose Estimation from Dose-Length Product in Lung Computed Tomography Using Monte Carlo Simulation.

Fallahmohammadi Gholamreza, Nodeh Zeinab Kordzini, Mahdavi Mohammad

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Computed tomography (CT) imaging has a large portion in the dose of patients from radiological procedures; therefore, accurate calculation of radiation risk estimation in this modality is inevitable. In this study, a method for determining the patient-specific effective dose using the dose-length product (DLP) index in lung CT scan using Monte Carlo (MC) simulation is introduced.

METHODS

EGSnrc/BEAMnrc MC code was used to simulate a CT scanner. The DOSxyznrc simulation code was used to simulate a specific voxelized phantom from the patient's lungs and irradiate it according to X-ray parameter of routing lung CT scan, and dose delivered to thorax organs was calculated. Three types of phantoms were simulated according to three different body habits (slim, standard, and fat patients) in two groups of men and women. A factor was used to convert the relative dose per particle in MC code to the absolute dose. The dose was calculated in all lung organs, and the effective dose was calculated for all three groups of patient body habits. DLP index and volume CT dose index (CTDIvol) were extracted from the patient's dose report in the CT scanner. The DLP to effective dose conversion factor (k-factor) for patients with different body habitus was calculated.

RESULTS

Lung radiation dose in slim, standard, and fat patients in men was 0.164, 0.103, and 0.078 mGy/mAs and in women was 0.164, 0.105, and 0.079 mGy/mAs, respectively. The k-factor in the group of slim patients, especially in women, was higher than in other groups.

CONCLUSIONS

CT scan dose indexes for slim patients are reported to be underestimated in studies. The dose report in CT scan systems should be modified in proportion to the patient's body habitus, to accurately estimate the radiation risk.

Для цитирования: Fallahmohammadi Gholamreza, Nodeh Zeinab Kordzini, Mahdavi Mohammad. Patient-specific Effective Dose Estimation from Dose-Length Product in Lung Computed Tomography Using Monte Carlo Simulation.. Journal of medical signals and sensors. 2024. DOI: 10.4103/jmss.jmss_53_22.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.