MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10278-024-01157-z

Медицинская библиотека · Journal of imaging informatics in medicine · 2024

A Novel Radiology Communication Tool to Reduce Workflow Interruptions: Clinical Evaluation of RadConnect.

Sevenster Merlijn, Hergaarden Kenneth F M, Hertgers Omar, Kruithof Natalie H M, Roelofs Joost J H, Foster-Dingley Jessica C, Romeijn Stephan R, Nguyen Duy Duc, Vosbergen Sandra, Lamb Hildo J

СтатьяПеревод пока не подготовлен

Аннотация

Despite the importance of communication, radiology departments often depend on communication tools that were not created for the unique needs of imaging workflows, leading to frequent radiologist interruptions. The objective of this study was test the hypothesis that a novel asynchronous communication tool for the imaging workflow (RadConnect) reduces the daily average number of synchronous (in-person, telephone) communication requests for radiologists. We conducted a before-after study. Before adoption of RadConnect, technologists used three conventional communication methods to consult radiologists (in-person, telephone, general-purpose enterprise chat (GPEC)). After adoption, participants used RadConnect as a fourth method. Technologists manually recorded every radiologist consult request related to neuro and thorax CT scans in the 40 days before and 40 days after RadConnect adoption. Telephone traffic volume to section beepers was obtained from the hospital telephone system for the same period. The value and usability experiences were collected through an electronic survey and structured interviews. RadConnect adoption resulted in 53% reduction of synchronous (in-person, telephone) consult requests: from 6.1 ± 4.2 per day to 2.9 ± 2.9 (P < 0.001). There was 77% decrease (P < 0.001) in telephone volume to the neuro and thorax beepers, while no significant volume change was noted to the abdomen beeper (control group). Survey responses (46% response rate) and interviews confirmed the positive impact of RadConnect on interruptions. RadConnect significantly reduced radiologists' telephone interruptions. Study participants valued the role-based interaction and prioritized worklist overview in the survey and interviews. Findings from this study will contribute to a more focused work environment.

Для цитирования: Sevenster Merlijn, Hergaarden Kenneth F M, Hertgers Omar, Kruithof Natalie H M, Roelofs Joost J H, Foster-Dingley Jessica C, Romeijn Stephan R, Nguyen Duy Duc, Vosbergen Sandra, Lamb Hildo J. A Novel Radiology Communication Tool to Reduce Workflow Interruptions: Clinical Evaluation of RadConnect.. Journal of imaging informatics in medicine. 2024. DOI: 10.1007/s10278-024-01157-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.