Improvements of the shape and strength of the diaphragm after endoscopic lung volume reduction.

Taton Olivier, Gevenois Pierre Alain, Van Muylem Alain, Bondue Benjamin, Van Laethem Sébastien, Leduc Dimitri

СтатьяПеревод пока не подготовлен

Аннотация

RATIONALE: Endoscopic lung volume reduction improves lung function, quality of life and exercise capacity in severe emphysema patients. However, its effect on the diaphragm function is not well understood. We hypothesised that endoscopic lung volume reduction increases its strength by modifying its shape.

OBJECTIVES

To investigate changes in both diaphragm shape and strength induced by the insertion of endobronchial valves.

METHODS

In 19 patients, both the diaphragm shape and strength were investigated respectively by 3D Slicer software applied on CT scans acquired at functional residual capacity and by transdiaphragmatic pressure measurements by bilateral magnetic stimulation of the phrenic nerves before and 3 months after unilateral valves insertion.

MEASUREMENTS AND MAIN

RESULTS

After lung volume reduction (median (IQR), 434 mL (-597 to -156], p<0.0001), diaphragm strength increased (transdiaphragmatic pressure: 3 cmH2O (2.3 to 4.2), p<0.0001). On the treated side, this increase was associated with an increase in the coronal (16 mm (13 to 24), p<0.0001) and sagittal (26 mm (21 to 30), p<0.0001) lengths as well as in the area of the zone of apposition (62 cm2 (3 to 100), p<0.0001) with a decrease in the coronal (8 mm (-12 to -4), p<0.0001) and sagittal (9 mm (-18 to -2), p=0.0029) radii of curvature.

CONCLUSIONS

Endoscopic lung volume reduction modifies the diaphragm shape by increasing its length and its zone of apposition and by decreasing its radius of curvature on the treated side, resulting in an increase in its strength.

TRIAL REGISTRATION NUMBER: NCT05799352.

Для цитирования: Taton Olivier, Gevenois Pierre Alain, Van Muylem Alain, Bondue Benjamin, Van Laethem Sébastien, Leduc Dimitri. Improvements of the shape and strength of the diaphragm after endoscopic lung volume reduction.. Thorax. 2024. DOI: 10.1136/thorax-2024-221375.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.