MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm13113242

Медицинская библиотека · Journal of clinical medicine · 2024

The Value of Ischemic Cardiac Biomarkers to Predict Spontaneous Breathing Trial or Extubation Failure: A Systematic Review.

Groenland Carline N L, Blijleven Maud A, Ramzi Imane, Dubois Eric A, Heunks Leo, Endeman Henrik, Wils Evert-Jan, Baggen Vivan J M

СтатьяОбзорПеревод пока не подготовлен

Аннотация

Background

It is unclear whether other cardiac biomarkers than NT-proBNP can be useful in the risk stratification of patients weaning from mechanical ventilation. The aim of this study is to summarize the role of ischemic cardiac biomarkers in predicting spontaneous breathing trial (SBT) or extubation failure.

Methods

We systematically searched Embase, MEDLINE, Web of Science, and Cochrane Central for studies published before January 2024 that reported the association between ischemic cardiac biomarkers and SBT or extubation failure. Data were extracted using a standardized form and methodological assessment was performed using the QUIPS tool.

Results

Seven observational studies investigating four ischemic cardiac biomarkers (Troponin-T, Troponin-I, CK-MB, Myoglobin) were included. One study reported a higher peak Troponin-I in patients with extubation failure compared to extubation success (50 ng/L [IQR, 20-215] versus 30 ng/L [IQR, 10-86], p = 0.01). A second study found that Troponin-I measured before the SBT was higher in patients with SBT failure in comparison to patients with SBT success (100 ± 80 ng/L versus 70 ± 130 ng/L, p = 0.03). A third study reported a higher CK-MB measured at the end of the SBT in patients with weaning failure (SBT or extubation failure) in comparison to weaning success (8.77 ± 20.5 ng/mL versus 1.52 ± 1.42 ng/mL, p = 0.047). Troponin-T and Myoglobin as well as Troponin-I and CK-MB measured at other time points were not found to be related to SBT or extubation failure. However, most studies were underpowered and with high risk of bias.

Conclusions

The association with SBT or extubation failure is limited for Troponin-I and CK-MB and appears absent for Troponin-T and Myoglobin, but available studies are hampered by significant methodological drawbacks. To more definitively determine the role of ischemic cardiac biomarkers, future studies should prioritize larger sample sizes, including patients at risk of cardiac disease, using stringent SBTs and structured timing of laboratory measurements before and after SBT.

Для цитирования: Groenland Carline N L, Blijleven Maud A, Ramzi Imane, Dubois Eric A, Heunks Leo, Endeman Henrik, Wils Evert-Jan, Baggen Vivan J M. The Value of Ischemic Cardiac Biomarkers to Predict Spontaneous Breathing Trial or Extubation Failure: A Systematic Review.. Journal of clinical medicine. 2024. DOI: 10.3390/jcm13113242.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.