MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/embc58623.2025.11252782

Медицинская библиотека · Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2025

Exploring Position, Velocity, and Torque Control via Minimal sEMG Calibration for Robotic Ankle Prostheses.

Scheidl Marc-Anton, Braun Hannah, Behrendt Jacob, Castellini Claudio

СтатьяПеревод пока не подготовлен

Аннотация

Utilizing myoelectric control systems in robotic lower-limb prosthetics is becoming increasingly prevalent, capturing user intent. However, AI-based myoelectric systems often experience high latency and require extensive training data and calibration. Our study introduces a minimalist ridge regression approach for interpreting surface electromyography signals, enabling real-time control of ankle prosthetics. The proof-of-concept system features three open-loop control modes: Position, Velocity, and Torque, which require minimal calibration. Five able-bodied participants participated in a Target Achievement Control test with varying levels of difficulty. Velocity control yielded the highest Completion Rate (CR = 83.3%, p = 0.031 vs Torque) but differences in Overshoot and Movement Time were not statistically significant. Position control achieved solid performance (CR = 71.4 %), whereas direct Torque control suffered from large variability (CR = 40.0 %). The results emphasize the promise of ridge regression for real-time myoelectric control, which could lead to affordable, low-latency prosthetic operation.

Для цитирования: Scheidl Marc-Anton, Braun Hannah, Behrendt Jacob, Castellini Claudio. Exploring Position, Velocity, and Torque Control via Minimal sEMG Calibration for Robotic Ankle Prostheses.. Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. 2025. DOI: 10.1109/embc58623.2025.11252782.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.