m+Medelevator.RU
← Поиск публикаций
Journal of neurophysiology · 2025

Investigating motor unit firing rates during arm cycling compared with intensity-matched isometric contractions in humans.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Basile Daniel C, Wira Alysha D, Rice Charles L, Power Kevin E

Аннотация

Studies in humans have not assessed motor unit firing rates (MUFRs) recorded from intramuscular electromyography (EMG) during a rhythmic locomotor output. Using arm cycling as a model of locomotor-generated activity, the purpose was to determine whether MUFRs differed during arm cycling compared with intensity-matched isometric contractions. We hypothesized that MUFRs would be greater during arm cycling than isometric contractions, assessed at various working intensities. Young males (n = 10) and females (n = 4) completed arm cycling bouts and isometric contractions of the elbow flexors. Indwelling fine-wire electrodes were inserted into the biceps brachii to record MUFRs during arm cycling with combinations of two power outputs (25 W and 50 W) and cadences (30 rpm and 60 rpm), and subsequently compared with intensity-matched isometric contractions. Motor unit recordings were analyzed during the flexion phase of arm cycling when biceps brachii EMG activity was high, and with the forearms in a neutral grip position. Results indicated that MUFRs were significantly higher during arm cycling compared with isometric contractions (P = 0.003), and MUFRs increased with greater cycling intensity (P < 0.001). Higher MUFRs demonstrated during arm cycling were likely influenced by greater descending drive and/or enhanced spinal motoneuron excitability, facilitated through central pattern generator (CPG)-mediated changes to intrinsic motoneuron properties. Thus, different neural control strategies are used during rhythmic locomotor output compared with isometric contractions in humans.NEW & NOTEWORTHY Motor unit firing rates (MUFRs) during an upper-limb locomotor task have yet to be recorded in humans, and behavior of the active motor units during dynamic central pattern generator (CPG)-mediated locomotor activity is currently unknown. The present study used indwelling fine-wire electrodes to record MUFRs during arm cycling and compared the firing rates to intensity-matched isometric contractions. Results demonstrated that MUFRs were significantly higher during arm cycling, indicating different neural control strategies between locomotor outputs and isometric contractions.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты