MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0360-3016(02)02853-5

Медицинская библиотека · International journal of radiation oncology, biology, physics · 2002

What margins are necessary for incorporating mediastinal nodal mobility into involved-field radiotherapy for lung cancer?

van Sörnsen de Koste John R, Lagerwaard Frank J, Nijssen-Visser Margriet R J, Schuchhard-Schipper Regine, Joosten Hans, Senan Suresh

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The mobility of mediastinal nodes was studied on multiple CT scans of the thorax from patients with non-small-cell lung cancer.

PATIENTS AND

METHODS

A total of 10 enlarged mediastinal nodes/masses were identified in 8 patients with non-small-cell lung cancer. Nodal locations were classified using the Naruke/ATS-LCSG system, and between 3 and 6 scans were available for each site. The CT data sets were coregistered, and the contoured nodes were automatically projected onto the initial planning CT scan. An encompassing nodal volume (ENV) of all contours of a particular node was manually contoured on all scans. Individual nodal volumes were expanded in three dimensions to establish additional margins required to encompass the ENV.

RESULTS

The mean volume of nodes studied ranged from 0.8 to 23.2 cc. The addition to individual nodes of a margin of 5 mm was found to result in a mean ENV coverage of >or=95% at all sites. For individual nodes at locations N4R, N5, and N6, however, the coverage ranged from 87.8% to 92.6%.

CONCLUSION

The addition of a margin of 5 mm to individual mediastinal nodes seems to be adequate to account for variations in both contouring and mobility.

Для цитирования: van Sörnsen de Koste John R, Lagerwaard Frank J, Nijssen-Visser Margriet R J, Schuchhard-Schipper Regine, Joosten Hans, Senan Suresh. What margins are necessary for incorporating mediastinal nodal mobility into involved-field radiotherapy for lung cancer?. International journal of radiation oncology, biology, physics. 2002. DOI: 10.1016/s0360-3016(02)02853-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.