DOI 10.1200/jco.2006.08.4228

Медицинская библиотека · Journal of clinical oncology : official journal of the American Society of Clinical Oncology · 2007

Prospective multicentric randomized study comparing periareolar and peritumoral injection of radiotracer and blue dye for the detection of sentinel lymph node in breast sparing procedures: FRANSENODE trial.

Rodier Jean-François, Velten Michel, Wilt Marc, Martel Pierre, Ferron Gwanaël, Vaini-Elies Véronique, Mignotte Hervé, Brémond Alain, Classe Jean-Marc, Dravet François, Routiot Thierry, de Lara Christine Tunon, Avril Antoine, Lorimier Gérard, Fondrinier Eric, Houvenaeghel Gilles, Avigdor Sandrine

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the optimal injection path for blue dye and radiocolloid for sentinel lymph node (SLN) biopsy in early breast cancer.

PATIENTS AND

METHODS

A prospective randomized multicentric study was initiated to compare the peritumoral (PT) injection site to the periareolar (PA) site in 449 patients.

RESULTS

The detection rate of axillary SLN by lymphoscintigraphy was significantly higher (P = .03) in the PA group (85.2%) than in the PT group (73.2%). Intraoperative detection rate by blue dye and/or gamma probe was similar (99.11%) in both groups. The rate of SLN detection was somewhat higher in the PA group than in the PT group: 95.6% versus 93.8% with blue dye (P = .24) and 98.2% versus 96.0% by probe (P = .16), respectively. The number of SLNs detected by lymphoscintigraphy and by probe was significantly higher in the PA group than in the PT group, 1.5 versus 1.2 (P = .001) and 1.9 versus 1.7 (P = .02). The blue and hot concordance was 95.6% in the PA group and 91.5% in the PT group (P = .08). The mean ex vivo count of the SLN was significantly higher in the PA group than in the PT group (P < .0001).

CONCLUSION

This study strongly validates the PA injection technique given the high detection rate (99.1%) of SLN and the high concordance (95.6%) between blue dye and the radiotracer, as well as higher significant ex and in vivo counts, improving SLN probe detection.

Для цитирования: Rodier Jean-François, Velten Michel, Wilt Marc, Martel Pierre, Ferron Gwanaël, Vaini-Elies Véronique, Mignotte Hervé, Brémond Alain, Classe Jean-Marc, Dravet François, Routiot Thierry, de Lara Christine Tunon, Avril Antoine, Lorimier Gérard, Fondrinier Eric, Houvenaeghel Gilles, Avigdor Sandrine. Prospective multicentric randomized study comparing periareolar and peritumoral injection of radiotracer and blue dye for the detection of sentinel lymph node in breast sparing procedures: FRANSENODE trial.. Journal of clinical oncology : official journal of the American Society of Clinical Oncology. 2007. DOI: 10.1200/jco.2006.08.4228.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.