m+Medelevator.RU
← Поиск публикаций
Seminars in dialysis · 2022

The use of medium cutoff dialyzers in patients with multiple myeloma and acute kidney injury requiring hemodialysis: A systematic review.

Систематический обзорСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Koniman Riece, Teo Su Hooi, Kaushik Manish, Nagarajan Chandramouli, Tan Melinda Si Yun, Tan Han Khim, Ramirez Maria Erika Gapas, Lim Cynthia Ciwei, S.I.N:G.A.P.O.R.E Initiative (Science In Nephrology: Growth And Progress Of Research & Education)

Аннотация

BACKGROUND: Patients with multiple myeloma and high serum levels of circulating free light chains (FLC) have increased risk of acute kidney injury (AKI) secondary to cast nephropathy and is associated with poor survival. Despite removal of FLC by medium cutoff (MCO) dialyzer, the role of MCO hemodialysis (HD) in the treatment of cast nephropathy and its clinical benefits remain unknown.

METHODS: A systematic review was conducted to establish the effectiveness of MCO dialyzer and clinical outcomes, compared to other forms of dialyzers in the removal of FLC, in myeloma patients with AKI. The primary outcome was effectiveness of MCO-HD in reducing serum FLC. The secondary outcomes were HD independence, estimated glomerular filtrate rate, mortality rates, length of hospitalization, rebound of serum FLC before the next dialysis, removal of other molecules during dialysis, and adverse events.

RESULTS: We identified three case series, with a total of 17 patients. There were no randomized controlled trials (RCTs) or cohort studies. These case series showed that MCO dialyzer was effective in the removal of FLC and led to a reduction in FLC concentration post-dialysis. The majority of the case series did not have comparator arm and renal and/or other clinical outcomes.

CONCLUSION: MCO dialyzer appeared to be effective in the removal of FLC based on the existing limited data. However, more data, particularly large-scale RCTs, are needed to assess the use of MCO dialyzer in reducing serum FLC and its effect on clinical outcomes in patients with multiple myeloma and AKI.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты