MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2022.06.011

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2022

Application of cerebrospinal fluid free light chain in diagnosis of primary central nervous system lymphoma and monitoring of associated chemotherapy efficacy.

Hu Yao, Xiang Jin, Luo Xiao, Lu Meijuan, Xu Dongwen, Chen Bobin, Guan Ming

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Cerebrospinal fluid (CSF) free light chain (FLC) detection has been proposed as a tool for diagnosing primary central nervous system lymphoma (PCNSL), but there is no consensus on the appropriate reference range and its value for monitoring chemotherapy efficacy has not been investigated in Chinese PCNSL patients. We assessed the application potential of CSF FLC ratios for diagnosing PCNSL and monitoring associated treatment efficacy.

METHODS

Kappa (κ) and lambda (λ) FLC were measured by nephelometry in CSF samples of patients with PCNSL (n = 45), other neurological diseases (n = 30), and normal controls (n = 60). Results of κ/λ FLC ratios (FLCr) were correlated with patients' diagnoses and receiver operating characteristic analysis was used to determine accuracy. In PCNSL patients, FLCr analysis was compared between PCNSL before and after treatment.

RESULTS

κ FLC and FLCr concentrations in PCNSL were significantly higher than in patients without PCNSL (P < 0.05). The optimal cut-off for FLCr was 0.35, with diagnostic sensitivity and specificity of 78% and 72%, respectively. FLCr concentrations decreased after chemotherapy.

CONCLUSION

CSF FLC is a novel biomarker for diagnosis and chemotherapy efficacy monitoring in PCNSL.

Для цитирования: Hu Yao, Xiang Jin, Luo Xiao, Lu Meijuan, Xu Dongwen, Chen Bobin, Guan Ming. Application of cerebrospinal fluid free light chain in diagnosis of primary central nervous system lymphoma and monitoring of associated chemotherapy efficacy.. Clinica chimica acta; international journal of clinical chemistry. 2022. DOI: 10.1016/j.cca.2022.06.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.