MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2006.04.029

Медицинская библиотека · Ophthalmology · 2006

Whole-body positron emission tomography/computed tomography imaging and staging of orbital lymphoma.

Roe Richard H, Finger Paul T, Kurli Madhavi, Tena Lawrence B, Iacob Codrin E

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

To report the use of whole-body positron emission tomography fused with computed tomography (PET/CT) for the diagnosis and staging of orbital lymphoma.

DESIGN

Retrospective observational case series.

PARTICIPANTS

Four patients with biopsy-proven orbital lymphoma were evaluated by 18-fluoro-2-deoxyglucose whole-body PET/CT imaging.

METHODS

Positron emission tomography/CT images were studied for the presence of glucose uptake. Foci were considered suspicious based on their standardized uptake values (SUVs). Physiologic images (PET) and their anatomic counterparts (CT) were fused to allow form and function to be evaluated on the same diagnostic page.

MAIN OUTCOME MEASURES: Positron emission tomography/CT images were assessed for foci with abnormally high SUVs that correlated with biopsy-proven lymphoma.

RESULTS

Positron emission tomography/CT detected orbital lymphoma in 3 patients (75%). It also revealed systemic lymphoma in 2 of the 4 patients. The 2 patients found to have systemic lymphoma were diagnosed to have extranodal marginal zone B-cell orbital lymphoma of the mucosa-associated lymphoid tissue (MALT) type. Similarly, the 2 with negative PET/CT results also had orbital MALT-type lymphoma. We found that PET/CT imaging helped guide further management in all 4 patients.

CONCLUSIONS

Positron emission tomography/CT should be considered as a new method of diagnosing, staging, and restaging patients with orbital lymphomas.

Для цитирования: Roe Richard H, Finger Paul T, Kurli Madhavi, Tena Lawrence B, Iacob Codrin E. Whole-body positron emission tomography/computed tomography imaging and staging of orbital lymphoma.. Ophthalmology. 2006. DOI: 10.1016/j.ophtha.2006.04.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.