OBJECTIVES/HYPOTHESIS: Develop a patient-specific tissue engineered construct for laryngeal reconstruction following a partial laryngectomy.

STUDY

DESIGN

Bench and animal research.

METHODS

A construct made from a porous polyethylene scaffold shaped in a canine-specific configuration and seeded with autologous canine adipose-derived stem cells in fibrin glue was implanted in a canine following a partial laryngectomy. After 1 year, the construct was first evaluated in vivo with high-speed imaging and acoustic-aerodynamic measures. It was then explanted and evaluated histologically.

RESULTS

The canine study at 1 year revealed the construct provided voicing (barking) with acoustic and aerodynamic measures within normal ranges. The canine was able to eat and breathe normally without long-term support. The construct was integrated with epithelialization of all areas except the medial portion of the vocal fold structure. No anti-infective agents were needed after the standard perioperative medications were completed.

CONCLUSION

This study provided a successful first step toward developing a patient-specific composite construct for patients undergoing partial laryngectomies.

LEVEL OF EVIDENCE: NA Laryngoscope, 132:S1-S11, 2022.

Для цитирования: Lott David G, Shah Manisha, Myers Cheryl, McPhail Michael, Neubauer Juergen, Struthers Jason, Madsen Cathy S, Grandjean Danielle, Zacharias Stephanie R C, Tchoukalova Yourka D. A Tissue Engineered Construct for Laryngeal Regeneration: A Proof-of-Concept Device Design Study.. The Laryngoscope. 2022. DOI: 10.1002/lary.30029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.