[Normal values for solid state high resolution anorectal manometry in healthy adult volunteers].

Wang A J, Shi Y Q, Zheng X L, He X X, Zhou X J, Li H M, Wang T, Xiong H F, Xie Y, Lyu N H

СтатьяПеревод пока не подготовлен

Аннотация

Objective

To explore the normal values for two-dimension solid state high resolution anorectal manometry (HRAM) in healthy adult volunteers.

Methods

The healthy adult volunteers were recruited by advertisement and underwent solid state HRAM in the left lateral position. Anorectal pressures and rectal sensation were recorded and analyzed.

Results

(1) A total of 126 Chinese healthy adult volunteers (male: 50 cases (39.7%); age: (37.5±14.2) years old ) were recruited in this study. (2) Mean anal resting pressure (MERP) was (71.8±17.3) mmHg (1 mmHg=0.133 kPa). Maximum anal resting pressure (MARP) was (79.3±17.8) mmHg, Maximum anal squeeze pressure (MSP) was (178.7±52.8) mmHg. Anal high pressure zone (HPZ) length was (3.4±0.6) cm. During simulated evacuation, residual anal pressure (RAP) was (63.8±20.5) mmHg, and anal relaxation rate (ARR) was (37.0±11.5)%. Rectal threshold volume for first sensation (FST), desire to defecate (DDT), urgency to defecate (UDT) and maximum discomfort (MDT) was (47.4±10.0) ml, (84.5±18.2) ml, (125.8±28.5) ml, and (175.5±36.1) ml, respectively. (3) Compared with female subjects, male subjects had higher MSP[(211.0±50.7) mmHg vs (157.5±42.5) mmHg], RAP[(71.6±18.1) mmHg vs (58.8±20.5) mmHg]and rectal MDT[(187.0±36.4) mmHg vs (168.0±34.1)mmHg], but lower ARR[(32.1±8.0)% vs (40.2±12.3)%], all P<0.01. (4) MERP, MARP, MSP and rectal MDT were higher in young group (≤40 years old), all P<0.05.

Conclusions

These observations provide normal values for two-dimension solid state HRAM, which have significant difference between genders and different age groups.

Для цитирования: Wang A J, Shi Y Q, Zheng X L, He X X, Zhou X J, Li H M, Wang T, Xiong H F, Xie Y, Lyu N H. [Normal values for solid state high resolution anorectal manometry in healthy adult volunteers].. Zhonghua nei ke za zhi. 2017. DOI: 10.3760/cma.j.issn.0578-1426.2017.08.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.