Difference in the airway luminal area between the standing and supine positions using upright and conventional computed tomography.

Matsumoto Shunsuke, Yamada Yoshitake, Yamada Minoru, Chubachi Shotaro, Yokoyama Yoichi, Matsuoka Shiho, Tanabe Akiko, Niijima Yuki, Murata Mitsuru, Fukunaga Koichi, Jinzaki Masahiro

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

No clinical studies to date have compared the airway luminal area between supine and standing positions. Our aim was therefore to compare the airway luminal area between these two positions on computed tomography (CT) and to determine its correlation with forced expiratory volume in 1 s (FEV1). Thirty-two asymptomatic volunteers underwent both conventional (supine position) and upright (standing position) CT during deep inspiration breath-holding. Pulmonary function tests were conducted on the same day. We measured the airway luminal area on CT in each position. Paired t-tests and Pearson's correlation coefficients were used for statistical analysis. The average luminal areas of the trachea, right and left main bronchi, and average third-generation airway were greater in the standing than the supine position by 3.4%, 6.1%, 5.5%, and 5.2%, respectively. The correlation coefficients between airway luminal areas and FEV1 tended to be higher in the standing than the supine position; this correlation was highest for the average third-generation airway (r = 0.70, P < 0.0001). The airway luminal areas of the trachea, bilateral main bronchi, and average third-generation airway were greater in the standing than the supine position. The average third-generation airway area in the standing position had the highest correlation with FEV1.

Для цитирования: Matsumoto Shunsuke, Yamada Yoshitake, Yamada Minoru, Chubachi Shotaro, Yokoyama Yoichi, Matsuoka Shiho, Tanabe Akiko, Niijima Yuki, Murata Mitsuru, Fukunaga Koichi, Jinzaki Masahiro. Difference in the airway luminal area between the standing and supine positions using upright and conventional computed tomography.. Clinical anatomy (New York, N.Y.). 2021. DOI: 10.1002/ca.23763.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.