DOI 10.1097/jom.0000000000001388
EBUS-TBNA Cytology Specimens are Predictive of Occupational Dust Exposure in Patients With Bilateral Mediastinal and Hilar Lymphadenopathy.
Аннотация
OBJECTIVES
The aim of this study was to describe the cytological features of patients with significant occupational dust exposure presenting with benign bilateral mediastinal and hilar lymphadenopathy (BHL).
METHODS
A retrospective cohort study including patients undergoing EBUS-TBNA for investigation of benign BHL. Patient characteristics, dust exposure history, radiology, and cytology samples from EBUS-TBNA were assessed.
RESULTS
EBUS-TBNA cytology in patients with exposure showed a significant increase in the presence of birefringent fibers (60.7% vs 19.2%, P = 0.001) and intracellular carbon pigment (75.0% vs 28.9%, P = 0.001) compared with patients without exposure. The presence of these two features together yielded a sensitivity of 53.6% and a specificity of 88.5%.
CONCLUSION
In patients with BHL and a history of occupational dust exposure, the presence of birefringent fibers and intracellular carbon pigment in EBUS-TBNA cytology samples may assist in a diagnosis of lymphadenopathy due to occupational dust exposure.